Solar Calculator Canada

Solar Power Calculator for Bruderheim, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bruderheim
  • GPS Coordinates: 53.7997222, -112.9283333
  • Elevation: 631 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bruderheim: 44o
  • Average yearly irradiance: 1425.75 kWh/m2
  • Average yearly power output: 120581 kWh
Sun Path Bruderheim

Average yearly irradiance delivered by the Sun in Bruderheim is 1425.75/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 120581 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.49 46.27
February 2.47 69.26
March 3.54 109.87
April 5.09 152.6
May 5.81 180.24
June 5.67 169.99
July 6.1 189.11
August 5.55 172.07
September 4.52 135.6
October 3.26 101.1
November 1.97 59.16
December 1.31 40.46
Total yearly 1425.75

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 139.54 4325.84
February 228.1 6386.72
March 316.33 9806.35
April 436.9 13107
May 482.69 14963.2
June 459.63 13788.9
July 488.49 15143.3
August 448.39 13900.2
September 375.09 11252.8
October 282.09 8744.75
November 178.73 5361.8
December 122.57 3799.54
Total yearly 120581

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bruderheim solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 83.08 2575.38
February 157.97 4423.12
March 260 8060.02
April 409.63 12288.9
May 496.79 15400.4
June 493.8 14814
July 513.56 15920.4
August 437.77 13571
September 323.9 9717.06
October 209.81 6504.06
November 111.51 3345.39
December 69.22 2145.94
Total yearly 108766

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 95.49 2960.04
February 174.03 4872.74
March 274.5 8509.57
April 420.1 12602.9
May 499.71 15491
June 492.76 14782.8
July 514.71 15955.9
August 445.3 13804.2
September 337.95 10138.5
October 226.65 7026.24
November 126.25 3787.55
December 80.79 2504.34
Total yearly 112436

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 106.87 3312.97
February 188.55 5279.31
March 287.11 8900.26
April 428.25 12847.6
May 500.16 15505
June 489.4 14681.9
July 513.32 15912.8
August 450.52 13966.1
September 349.83 10494.8
October 241.77 7494.91
November 139.76 4192.94
December 91.43 2834.21
Total yearly 115423

Bruderheim Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 117.2 3633.29
February 201.5 5642.06
March 297.78 9231.31
April 433.9 13016.9
May 498.35 15448.8
June 483.82 14514.6
July 509.67 15799.8
August 453.29 14051.9
September 359.49 10784.8
October 255.11 7908.54
November 152.01 4560.18
December 101.12 3134.69
Total yearly 117727

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.77% angle of incidence loss and -3.35% temperature and irradiance loss. This totals to about -15.43%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: