Solar Calculator Canada

Solar Power Calculator for Canmore, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Canmore
  • GPS Coordinates: 51.0830555, -115.3683333
  • Elevation: 1312 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Canmore: 41o
  • Average yearly irradiance: 1348.78 kWh/m2
  • Average yearly power output: 116108 kWh
Sun Path Canmore

Average yearly irradiance delivered by the Sun in Canmore is 1348.78/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 116108 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.6 49.7
February 2.82 78.91
March 3.63 112.49
April 4.63 138.85
May 5.21 161.38
June 4.99 149.84
July 5.78 179.03
August 5.29 163.9
September 4.28 128.53
October 3.04 94.34
November 1.73 51.97
December 1.29 39.85
Total yearly 1348.78

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 147.89 4584.7
February 259.64 7269.8
March 327.84 10163
April 408.88 12266.4
May 445.97 13825
June 416.86 12505.7
July 470.09 14572.9
August 432.68 13413.1
September 359.26 10777.7
October 266.77 8269.97
November 158.49 4754.77
December 119.52 3705.16
Total yearly 116108

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Canmore solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 99.77 3092.74
February 194.27 5439.69
March 283.84 8799.05
April 392.41 11772.2
May 454.2 14080.1
June 438.6 13157.9
July 484.47 15018.5
August 421.57 13068.7
September 325.44 9763.08
October 212.35 6582.86
November 110.48 3314.38
December 77.38 2398.67
Total yearly 106488

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 110.36 3421.06
February 208.95 5850.54
March 295.33 9155.16
April 398.97 11969.2
May 455.01 14105.2
June 435.45 13063.5
July 483.76 14996.5
August 426.97 13235.9
September 337.06 10111.8
October 225.73 6997.72
November 120.9 3627.13
December 86.63 2685.46
Total yearly 109219

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.9 3716.8
February 221.98 6215.32
March 305.04 9456.17
April 403.48 12104.3
May 453.68 14064.2
June 430.59 12917.6
July 481.18 14916.7
August 430.1 13333.1
September 346.63 10399
October 237.51 7362.7
November 130.26 3907.82
December 94.97 2944.08
Total yearly 111338

Canmore Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 128.39 3979.95
February 233.35 6533.88
March 312.94 9701.25
April 405.89 12176.7
May 450.5 13965.5
June 424.76 12742.7
July 476.35 14766.8
August 430.96 13359.7
September 354.14 10624.2
October 247.65 7677.24
November 138.54 4156.3
December 102.41 3174.72
Total yearly 112859

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.76% angle of incidence loss and -1.63% temperature and irradiance loss. This totals to about -13.92%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Prince GeorgePrince RupertFlin FlonGrande PrairieThompsonFort St. JohnYarmouthChannel-Port aux BasquesGanderBanffLabrador CityHappy Valley - Goose BayHintonLa RongeHigh LevelChurchillFort Smithnear Watson Lake100km south from Hay RiverDawsonNorman WellsInuvikTorontoOttawaFrederictonMurdochville