Solar Calculator Canada

Solar Power Calculator for Mundare, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Mundare
  • GPS Coordinates: 53.5938889, -112.3416667
  • Elevation: 684 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Mundare: 44o
  • Average yearly irradiance: 1442.98 kWh/m2
  • Average yearly power output: 122855 kWh
Sun Path Mundare

Average yearly irradiance delivered by the Sun in Mundare is 1442.98/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 122855 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.52 47.17
February 2.59 72.4
March 3.51 108.79
April 5.07 152.2
May 5.87 182.09
June 5.64 169.07
July 6.1 189.01
August 5.62 174.19
September 4.71 141.31
October 3.46 107.41
November 1.95 58.53
December 1.32 40.82
Total yearly 1442.98

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 143.68 4454.16
February 240.86 6744.2
March 315.57 9782.82
April 439.33 13179.8
May 491.73 15243.5
June 459.12 13773.7
July 490.74 15213
August 456.06 14137.8
September 392.61 11778.4
October 301.71 9353
November 177.55 5326.39
December 124.79 3868.36
Total yearly 122855

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Mundare solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 84.13 2608.07
February 163.85 4587.78
March 257.68 7988.1
April 413.14 12394.2
May 508 15747.9
June 495.96 14878.8
July 518.28 16066.7
August 445.8 13819.9
September 338.11 10143.4
October 222.46 6896.35
November 111.05 3331.47
December 69.78 2163.16
Total yearly 110626

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 96.98 3006.4
February 181.14 5071.86
March 272.32 8441.84
April 423.64 12709.2
May 511.1 15844.2
June 494.77 14843
July 519.34 16099.6
August 453.57 14060.5
September 353.17 10595.2
October 240.76 7463.45
November 125.53 3765.98
December 81.57 2528.53
Total yearly 114430

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 108.79 3372.53
February 196.79 5510.2
March 285.05 8836.55
April 431.8 12953.9
May 511.66 15861.5
June 491.23 14736.8
July 517.83 16052.8
August 458.96 14227.7
September 365.92 10977.7
October 257.19 7972.86
November 138.81 4164.26
December 92.42 2865.12
Total yearly 117532

Mundare Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.53 3705.39
February 210.79 5902.02
March 295.85 9171.42
April 437.39 13121.8
May 509.9 15807
June 485.46 14563.7
July 513.94 15932.2
August 461.9 14318.9
September 376.32 11289.7
October 271.71 8422.93
November 150.83 4525.01
December 102.32 3172.02
Total yearly 119932

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.77% angle of incidence loss and -2.71% temperature and irradiance loss. This totals to about -14.86%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

PetitcodiacMemramcookMeducticSalisburyPort ElginBaddeckMillvilleChipmanCap-Pel�Hilton BeachStanleySaint-AntoineCentrevilleBathDoaktownRextonPerth-AndoverBlackvilleRogersvilleSaint-Louis de KentAroostookPlaster RockDrummondSaint-Fran�ois de MadawaskaSainte-Anne-de-MadawaskaMurdochville