Solar Calculator Canada

Solar Power Calculator for Ponoka, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Ponoka
  • GPS Coordinates: 52.675, -113.58
  • Elevation: 806 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Ponoka: 43o
  • Average yearly irradiance: 1466.84 kWh/m2
  • Average yearly power output: 123309 kWh
Sun Path Ponoka

Average yearly irradiance delivered by the Sun in Ponoka is 1466.84/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 123309 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.72 53.47
February 2.62 73.31
March 3.42 106.14
April 5.11 153.27
May 5.88 182.23
June 5.67 170.01
July 6.23 193.23
August 5.78 179.12
September 4.72 141.58
October 3.4 105.37
November 2.16 64.81
December 1.43 44.31
Total yearly 1466.84

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 158.66 4918.53
February 237.01 6636.39
March 299.85 9295.47
April 436.41 13092.2
May 487.69 15118.5
June 459.3 13779.1
July 497.15 15411.7
August 464.66 14404.5
September 389.41 11682.4
October 292.22 9058.7
November 194.08 5822.53
December 131.91 4089.25
Total yearly 123309

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Ponoka solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 97.02 3007.61
February 167.3 4684.51
March 250.47 7764.68
April 413.17 12395.2
May 503.39 15605.2
June 494.23 14826.8
July 523.71 16234.9
August 454.12 14077.7
September 339.35 10180.4
October 221.66 6871.37
November 124.94 3748.28
December 77.27 2395.31
Total yearly 111792

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 110.87 3436.93
February 183.65 5142.27
March 263.57 8170.62
April 422.87 12686
May 505.84 15681.1
June 492.63 14778.9
July 524.4 16256.3
August 461.85 14317.4
September 353.61 10608.4
October 238.54 7394.88
November 140.53 4215.86
December 89.42 2772.03
Total yearly 115461

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 123.55 3830.06
February 198.39 5554.82
March 274.87 8520.91
April 430.24 12907.1
May 505.84 15681
June 488.75 14662.6
July 522.56 16199.3
August 467.13 14481
September 365.61 10968.3
October 253.64 7862.69
November 154.77 4643.11
December 100.56 3117.37
Total yearly 118428

Ponoka Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 135.04 4186.15
February 211.48 5921.58
March 284.35 8815
April 435.11 13053.2
May 503.66 15613.4
June 482.72 14481.7
July 518.54 16074.8
August 469.73 14561.7
September 375.3 11259
October 266.89 8273.49
November 167.63 5028.83
December 110.67 3430.73
Total yearly 120700

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.74% angle of incidence loss and -3.96% temperature and irradiance loss. This totals to about -15.94%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: