Solar Power Calculator for Stavely, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Stavely
  • GPS Coordinates: 50.1611111, -113.6416667
  • Elevation: 1040 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Stavely: 42o
  • Average yearly irradiance: 1602.52 kWh/m2
  • Average yearly power output: 133198 kWh
Sun Path Stavely

Average yearly irradiance delivered by the Sun in Stavely is 1602.52/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 133198 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.2 68.13
February 3.01 84.34
March 4.1 127.02
April 5.2 156.03
May 5.78 179.29
June 5.77 173.23
July 6.68 207.03
August 6.12 189.6
September 5.24 157.07
October 3.76 116.56
November 2.66 79.7
December 2.08 64.53
Total yearly 1602.52

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 197.49 6122.13
February 265.99 7447.79
March 355.06 11006.8
April 438.8 13164.1
May 473.77 14686.9
June 463.41 13902.4
July 525.45 16288.8
August 483.39 14985
September 425.84 12775.2
October 318.97 9888.03
November 236 7079.87
December 188.75 5851.39
Total yearly 133198

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Stavely solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 127.93 3965.84
February 197.96 5543
March 302.94 9391.13
April 421.18 12635.5
May 493.31 15292.5
June 503.63 15108.9
July 557.72 17289.3
August 476.64 14776
September 376.13 11283.8
October 248.36 7699.13
November 158.59 4757.78
December 114.66 3554.53
Total yearly 121297

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 143.99 4463.8
February 214.39 6002.83
March 317.19 9832.87
April 429.71 12891.4
May 494.76 15337.5
June 500.67 15020
July 557.41 17279.7
August 483.81 14998.1
September 390.8 11724.1
October 265.81 8240.14
November 176.5 5295.04
December 131.56 4078.34
Total yearly 125164

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 158.64 4917.75
February 229.08 6414.36
March 329.39 10211.2
April 435.9 13077
May 493.89 15310.6
June 495.48 14864.3
July 554.63 17193.6
August 488.29 15136.8
September 402.99 12089.7
October 281.31 8720.69
November 192.79 5783.76
December 147.05 4558.44
Total yearly 128278

Stavely Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 171.83 5326.84
February 242.04 6777
March 339.52 10525.2
April 439.56 13186.7
May 491.04 15222.2
June 488.4 14652.1
July 549.5 17034.4
August 489.99 15189.7
September 412.65 12379.6
October 294.82 9139.56
November 207.43 6222.81
December 161.08 4993.55
Total yearly 130650

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -5.09% temperature and irradiance loss. This totals to about -16.88%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.