Solar Calculator Canada

Solar Power Calculator for Vermilion, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Vermilion
  • GPS Coordinates: 53.3547222, -110.8527778
  • Elevation: 616 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Vermilion: 44o
  • Average yearly irradiance: 1463.11 kWh/m2
  • Average yearly power output: 124691 kWh
Sun Path Vermilion

Average yearly irradiance delivered by the Sun in Vermilion is 1463.11/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 124691 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.58 48.9
February 2.46 68.83
March 3.72 115.23
April 5.08 152.47
May 5.92 183.67
June 5.49 164.68
July 6.21 192.37
August 5.63 174.38
September 4.85 145.63
October 3.56 110.37
November 2.02 60.58
December 1.48 46.01
Total yearly 1463.11

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 150.02 4650.72
February 231.14 6471.92
March 336.06 10417.9
April 439.44 13183.3
May 494.3 15323.2
June 445.91 13377.2
July 499.12 15472.8
August 456.26 14144
September 404.71 12141.4
October 309.62 9598.09
November 184.28 5528.38
December 141.34 4381.61
Total yearly 124691

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Vermilion solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 88.67 2748.62
February 160.33 4489.31
March 274.1 8496.97
April 413.55 12406.5
May 510.28 15818.6
June 481.86 14456
July 527 16337
August 445.97 13825.1
September 347.83 10435
October 227.93 7065.7
November 115.1 3453.08
December 78.71 2440.01
Total yearly 111972

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 101.93 3159.76
February 176.28 4935.73
March 289.8 8983.73
April 423.93 12717.9
May 513.54 15919.8
June 480.71 14421.4
July 528.17 16373.2
August 453.75 14066.1
September 363.38 10901.3
October 246.73 7648.7
November 130.11 3903.27
December 92.14 2856.29
Total yearly 115887

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 114.12 3537.61
February 190.71 5339.83
March 303.46 9407.16
April 431.83 12955
May 514.34 15944.5
June 477.29 14318.6
July 526.7 16327.8
August 459.18 14234.6
September 376.53 11296
October 263.62 8172.23
November 143.86 4315.9
December 104.5 3239.39
Total yearly 119089

Vermilion Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 125.2 3881.05
February 203.6 5700.73
March 315.05 9766.4
April 437.28 13118.3
May 512.68 15893.1
June 471.69 14150.8
July 522.72 16204.2
August 462.21 14328.4
September 387.26 11617.9
October 278.54 8634.64
November 156.32 4689.59
December 115.75 3588.32
Total yearly 121573

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -2.66% temperature and irradiance loss. This totals to about -14.78%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: