Solar Calculator Canada

Solar Power Calculator for Lumby, British Columbia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Lumby
  • GPS Coordinates: 50.250833, -118.961944
  • Elevation: 495 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Lumby: 38o
  • Average yearly irradiance: 1409.33 kWh/m2
  • Average yearly power output: 116139 kWh
Sun Path Lumby

Average yearly irradiance delivered by the Sun in Lumby is 1409.33/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 116139 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.29 40.06
February 2.42 67.62
March 3.47 107.44
April 4.84 145.05
May 5.74 178.02
June 5.54 166.1
July 6.57 203.67
August 6.05 187.67
September 4.61 138.24
October 2.9 89.87
November 1.56 46.73
December 1.25 38.86
Total yearly 1409.33

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 113.21 3509.52
February 212.28 5943.91
March 300.92 9328.52
April 411.14 12334.2
May 470.02 14570.6
June 445.69 13370.7
July 516.05 15997.4
August 477.63 14806.4
September 373.44 11203.3
October 244.25 7571.84
November 135.35 4060.5
December 111.03 3441.98
Total yearly 116139

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Lumby solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 82.52 2558.26
February 169.16 4736.42
March 266.11 8249.32
April 396.4 11891.9
May 479.44 14862.7
June 470.08 14102.4
July 535.61 16604
August 468.04 14509.3
September 336.71 10101.4
October 202.44 6275.73
November 101.85 3055.36
December 76.23 2363.24
Total yearly 109310

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 90.76 2813.55
February 181.13 5071.56
March 276.09 8558.93
April 403.01 12090.2
May 480.61 14899
June 467.86 14035.9
July 535.42 16598
August 474.38 14705.7
September 348.71 10461.3
October 214.46 6648.4
November 110.98 3329.29
December 85.53 2651.49
Total yearly 111863

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 98.2 3044.1
February 191.75 5369.07
March 284.46 8818.29
April 407.53 12225.9
May 479.44 14862.6
June 463.93 13917.9
July 532.41 16504.6
August 478.13 14821.9
September 358.57 10757.1
October 225.01 6975.32
November 119.21 3576.18
December 94 2913.92
Total yearly 113787

Lumby Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.82 3249.54
February 201.02 5628.47
March 291.18 9026.66
April 409.93 12298
May 475.87 14751.9
June 457.44 13723.2
July 526.63 16325.4
August 479.28 14857.7
September 366.27 10988.2
October 234.06 7255.89
November 126.52 3795.5
December 101.61 3149.99
Total yearly 115051

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.86% angle of incidence loss and -5.74% temperature and irradiance loss. This totals to about -17.59%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.