Solar Calculator Canada

Solar Power Calculator for Bathurst, New Brunswick, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bathurst
  • GPS Coordinates: 47.617966, -65.651080
  • Elevation: 7 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bathurst: 42o
  • Average yearly irradiance: 1475.52 kWh/m2
  • Average yearly power output: 125337 kWh
Sun Path Bathurst

Average yearly irradiance delivered by the Sun in Bathurst is 1475.52/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 125337 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.81 87.04
February 3.5 98.05
March 4.24 131.57
April 4.72 141.56
May 5.05 156.49
June 5.05 151.35
July 5.3 164.34
August 5.1 158.22
September 4.6 138.14
October 3.52 109.17
November 2.52 75.66
December 2.06 63.92
Total yearly 1475.52

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 266.01 8246.41
February 325.6 9116.81
March 381.34 11821.5
April 406.57 12197
May 417.74 12949.9
June 406.05 12181.5
July 419.9 13016.8
August 406.65 12606.1
September 377.13 11313.8
October 300.64 9319.91
November 222.78 6683.51
December 189.81 5884
Total yearly 125337

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bathurst solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 179.68 5570.19
February 247.78 6937.71
March 333.52 10339.3
April 398.21 11946.2
May 441.94 13700.2
June 444.35 13330.4
July 451.83 14006.7
August 410.91 12738.1
September 342.85 10285.5
October 242.4 7514.51
November 158.28 4748.29
December 124.12 3847.63
Total yearly 114965

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 200.03 6200.96
February 266.94 7474.4
March 347.23 10764.1
April 404.59 12137.6
May 442 13702.1
June 441.08 13232.5
July 449.97 13949.1
August 414.83 12859.8
September 354 10620
October 257.27 7975.52
November 173.63 5208.95
December 139.4 4321.3
Total yearly 118446

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 218.52 6774.16
February 284.05 7953.51
March 358.75 11121.2
April 408.79 12263.8
May 440.05 13641.5
June 435.97 13079.1
July 446.13 13830
August 416.73 12918.6
September 362.99 10889.8
October 270.36 8381.1
November 187.55 5626.42
December 153.37 4754.34
Total yearly 121234

Bathurst Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 235.12 7288.76
February 299.07 8373.97
March 368.05 11409.5
April 410.75 12322.5
May 435.79 13509.4
June 429.44 12883.1
July 440.92 13668.6
August 416.27 12904.4
September 369.81 11094.3
October 281.61 8729.99
November 199.98 5999.39
December 165.98 5145.43
Total yearly 123329

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.8% angle of incidence loss and -2.9% temperature and irradiance loss. This totals to about -15.06%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

PetawawaPowassanKillarneyLac-PoulinBlind RiverLac-SaguayGaskiers-Point La HayeTignishHarbour Main-Chapel's Cove-LakeviewPetty Harbour-Maddox CoveSt. Bernard's-Jacques FontaineParadiseSpaniard's BayBishop's CoveBryant's CoveNeebingPort au Port West-Aguathuna-Felix CoveIrishtown-SummersideCochraneGlenburnie-Birchy Head-Shoal BrookCottlesvilleTritonLushes Bight - Beaumont - Beaumont NorthFogo IslandSioux LookoutMurdochville