Solar Calculator Canada

Solar Power Calculator for Riverside-Albert, New Brunswick, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Riverside-Albert
  • GPS Coordinates: 45.743149, -64.740286
  • Elevation: 8 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Riverside-Albert: 39o
  • Average yearly irradiance: 1503.15 kWh/m2
  • Average yearly power output: 127845 kWh
Sun Path Riverside-Albert

Average yearly irradiance delivered by the Sun in Riverside-Albert is 1503.15/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 127845 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.72 84.46
February 3.44 96.24
March 4.31 133.55
April 4.8 144.09
May 4.98 154.43
June 5.01 150.35
July 5.48 169.9
August 5.39 167.08
September 4.83 144.85
October 3.71 115.12
November 2.63 78.75
December 2.07 64.3
Total yearly 1503.15

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 255.12 7908.62
February 317.1 8878.7
March 386.08 11968.6
April 413.42 12402.6
May 415.35 12876
June 407.68 12230.3
July 439.1 13612.1
August 433.12 13426.8
September 397.76 11932.7
October 316.9 9823.78
November 231.36 6940.72
December 188.53 5844.37
Total yearly 127845

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Riverside-Albert solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.97 5641.19
February 250.74 7020.77
March 344.5 10679.4
April 408.28 12248.5
May 439.24 13616.3
June 443.43 13302.8
July 470.5 14585.5
August 438.32 13588
September 366.17 10985
October 261.94 8120.04
November 171.17 5135.05
December 131.47 4075.55
Total yearly 118998

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 200.39 6212.17
February 268.18 7509.18
March 357.29 11076
April 413.67 12410.2
May 438.49 13593.1
June 439.59 13187.8
July 468.01 14508.4
August 441.8 13695.8
September 377.08 11312.4
October 276.92 8584.61
November 186.44 5593.26
December 145.71 4517.02
Total yearly 122200

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 217.06 6728.89
February 283.68 7943.01
March 367.91 11405.3
April 416.88 12506.5
May 435.5 13500.6
June 434.39 13031.8
July 463.93 14381.8
August 443.09 13735.7
September 385.73 11572
October 290.02 8990.69
November 200.23 6006.98
December 158.66 4918.42
Total yearly 124722

Riverside-Albert Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 231.95 7190.41
February 297.18 8321.05
March 376.33 11666.2
April 417.85 12535.5
May 430.39 13342.1
June 426.85 12805.5
July 457.47 14181.5
August 441.95 13700.5
September 392.1 11762.9
October 301.19 9337.04
November 212.5 6374.89
December 170.28 5278.72
Total yearly 126496

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.83% angle of incidence loss and -2.75% temperature and irradiance loss. This totals to about -14.95%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

SlocanGold RiverCreelmanKenosee LakeMaryfieldFillmoreNoblefordVanguardKasloTahsisLangSilvertonNevilleElkhornZeballosNew DenverKennedyAvonleaTompkinsWilcoxWindthorstHodgevilleCarmangayCoderreCanal FlatsMurdochville