Solar Calculator Canada

Solar Power Calculator for River Hebert, Nova Scotia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: River Hebert
  • GPS Coordinates: 45.69028, -64.378037
  • Elevation: 11 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for River Hebert: 40o
  • Average yearly irradiance: 1505.31 kWh/m2
  • Average yearly power output: 128398 kWh
Sun Path River Hebert

Average yearly irradiance delivered by the Sun in River Hebert is 1505.31/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 128398 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.85 88.26
February 3.48 97.52
March 4.42 137.04
April 4.9 147.1
May 4.97 154.02
June 4.91 147.17
July 5.33 165.21
August 5.35 165.88
September 4.74 142.28
October 3.69 114.51
November 2.64 79.16
December 2.17 67.16
Total yearly 1505.31

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 267.06 8278.74
February 321.65 9006.3
March 396.94 12305.2
April 422.33 12669.9
May 415.12 12868.7
June 400.14 12004.1
July 428.15 13272.5
August 431.21 13367.5
September 391.57 11747.2
October 315.46 9779.24
November 232.63 6978.8
December 197.4 6119.46
Total yearly 128398

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

River Hebert solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.49 5812.25
February 252.96 7082.99
March 352.38 10923.8
April 416.08 12482.5
May 440.21 13646.5
June 436.9 13106.9
July 459.56 14246.3
August 435.62 13504.1
September 360.23 10807
October 259.38 8040.75
November 169.66 5089.81
December 134.75 4177.21
Total yearly 118920

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 207.06 6418.78
February 270.72 7580.14
March 365.91 11343.2
April 422 12660
May 439.52 13625.1
June 433.08 12992.5
July 457.27 14175.3
August 439.45 13622.9
September 371.03 11130.8
October 274.45 8507.81
November 185.28 5558.35
December 150 4649.86
Total yearly 122265

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 224.79 6968.62
February 286.5 8022.05
March 377.18 11692.5
April 425.65 12769.4
May 436.52 13532.1
June 427.94 12838.2
July 453.4 14055.5
August 440.98 13670.5
September 379.58 11387.3
October 287.62 8916.31
November 199.41 5982.22
December 163.89 5080.52
Total yearly 124915

River Hebert Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 240.67 7460.65
February 300.27 8407.43
March 386.15 11970.7
April 426.97 12809.1
May 431.41 13373.6
June 420.46 12613.9
July 447.15 13861.5
August 440.17 13645.3
September 385.86 11575.9
October 298.87 9265
November 212 6359.92
December 176.39 5468.01
Total yearly 126811

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.77% angle of incidence loss and -2.52% temperature and irradiance loss. This totals to about -14.7%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

SlocanGold RiverCreelmanKenosee LakeMaryfieldFillmoreNoblefordVanguardKasloTahsisLangSilvertonNevilleElkhornZeballosNew DenverKennedyAvonleaTompkinsWilcoxWindthorstHodgevilleCarmangayCoderreCanal FlatsMurdochville