Solar Calculator Canada

Solar Power Calculator for Burk's Falls, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Burk's Falls
  • GPS Coordinates: 45.6292, -79.40317
  • Elevation: 293 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Burk's Falls: 37o
  • Average yearly irradiance: 1499.55 kWh/m2
  • Average yearly power output: 125922 kWh
Sun Path Burk's Falls

Average yearly irradiance delivered by the Sun in Burk's Falls is 1499.55/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 125922 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.25 69.78
February 3.18 88.95
March 4.72 146.22
April 5.02 150.7
May 5.59 173.14
June 5.55 166.53
July 5.88 182.24
August 5.48 169.77
September 4.53 135.89
October 3.21 99.36
November 2.26 67.73
December 1.59 49.24
Total yearly 1499.55

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 210.87 6537.02
February 295.22 8266.08
March 421.6 13069.5
April 427.45 12823.5
May 456.84 14161.9
June 444.16 13325
July 466.05 14447.7
August 436.98 13546.4
September 368.1 11042.9
October 270.2 8376.31
November 196.22 5886.7
December 143.18 4438.66
Total yearly 125922

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Burk's Falls solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 158.02 4898.48
February 241.71 6767.8
March 375.41 11637.7
April 418.71 12561.4
May 477.51 14802.8
June 476.77 14303.2
July 494.34 15324.6
August 439.54 13625.8
September 341.4 10241.9
October 230.02 7130.58
November 151.65 4549.65
December 106.79 3310.58
Total yearly 119155

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 172.62 5351.11
February 257.06 7197.57
March 390.15 12094.7
April 424.6 12738.1
May 476.83 14781.7
June 472.57 14177
July 491.4 15233.4
August 442.93 13730.9
September 351.04 10531.3
October 241.94 7500.15
November 164.07 4921.99
December 116.85 3622.31
Total yearly 121880

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 185.76 5758.54
February 270.6 7576.73
March 402.45 12475.8
April 428.21 12846.4
May 473.57 14680.7
June 466.85 14005.4
July 486.83 15091.7
August 444 13764
September 358.61 10758.4
October 252.28 7820.7
November 175.2 5255.96
December 125.89 3902.65
Total yearly 123937

Burk's Falls Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 197.43 6120.21
February 282.3 7904.37
March 412.27 12780.3
April 429.51 12885.4
May 467.95 14506.5
June 458.51 13755.5
July 479.57 14866.7
August 442.72 13724.5
September 364.09 10922.6
October 261.01 8091.24
November 185.02 5550.71
December 133.92 4151.42
Total yearly 125259

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.89% angle of incidence loss and -3.92% temperature and irradiance loss. This totals to about -16.03%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

SlocanGold RiverCreelmanKenosee LakeMaryfieldFillmoreNoblefordVanguardKasloTahsisLangSilvertonNevilleElkhornZeballosNew DenverKennedyAvonleaTompkinsWilcoxWindthorstHodgevilleCarmangayCoderreCanal FlatsMurdochville