Solar Calculator Canada

Solar Power Calculator for Sundridge, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Sundridge
  • GPS Coordinates: 45.77988, -79.38064
  • Elevation: 339 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Sundridge: 38o
  • Average yearly irradiance: 1514.62 kWh/m2
  • Average yearly power output: 127615 kWh
Sun Path Sundridge

Average yearly irradiance delivered by the Sun in Sundridge is 1514.62/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 127615 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.49 77.29
February 3.5 98.13
March 4.78 148.11
April 4.98 149.47
May 5.54 171.7
June 5.56 166.66
July 5.77 178.84
August 5.41 167.58
September 4.55 136.5
October 3.15 97.74
November 2.3 69.12
December 1.73 53.48
Total yearly 1514.62

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 235.05 7286.55
February 327.12 9159.26
March 428.05 13269.5
April 424.61 12738.4
May 452.83 14037.6
June 444.7 13340.9
July 457.45 14181.1
August 431.42 13374
September 370.11 11103.4
October 265.92 8243.49
November 200.8 6023.97
December 156.66 4856.44
Total yearly 127615

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Sundridge solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 171.81 5326.23
February 262.29 7344.19
March 379.15 11753.7
April 416.48 12494.5
May 475.48 14740
June 479.66 14389.8
July 487.74 15120
August 435.15 13489.7
September 342.53 10276
October 225.61 6994.05
November 152.68 4580.26
December 113.01 3503.44
Total yearly 120012

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 188.6 5846.53
February 280.15 7844.19
March 394.36 12225.1
April 422.36 12670.8
May 474.76 14717.5
June 475.48 14264.3
July 484.82 15029.5
August 438.46 13592.4
September 352.32 10569.5
October 237.24 7354.31
November 165.55 4966.38
December 124.51 3859.74
Total yearly 122940

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 203.75 6316.38
February 296 8288.01
March 407.08 12619.5
April 425.98 12779.5
May 471.46 14615.4
June 469.81 14094.5
July 480.29 14889
August 439.52 13625
September 360.01 10800.4
October 247.32 7666.79
November 177.14 5314.07
December 134.93 4182.85
Total yearly 125191

Sundridge Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 217.26 6735
February 309.8 8674.32
March 417.28 12935.8
April 427.32 12819.6
May 465.83 14440.6
June 461.51 13845.2
July 473.14 14667.3
August 438.28 13586.6
September 365.61 10968.2
October 255.82 7930.44
November 187.4 5622.08
December 144.25 4471.84
Total yearly 126697

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.91% angle of incidence loss and -3.58% temperature and irradiance loss. This totals to about -15.74%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: