Solar Calculator Canada

Solar Power Calculator for Bois-des-Filion, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bois-des-Filion
  • GPS Coordinates: 45.6666667, -73.75
  • Elevation: 17 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bois-des-Filion: 39o
  • Average yearly irradiance: 1576.37 kWh/m2
  • Average yearly power output: 132697 kWh
Sun Path Bois-des-Filion

Average yearly irradiance delivered by the Sun in Bois-des-Filion is 1576.37/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 132697 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.82 87.53
February 3.47 97.3
March 4.47 138.6
April 5.08 152.42
May 5.55 172.05
June 5.54 166.22
July 5.87 181.98
August 5.72 177.36
September 4.87 146.15
October 3.47 107.64
November 2.88 86.49
December 2.02 62.65
Total yearly 1576.37

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 264.98 8214.45
February 322.26 9023.16
March 398.83 12363.6
April 431.44 12943.1
May 453.8 14067.7
June 442.47 13274.2
July 463.91 14381.3
August 455.86 14131.5
September 395.02 11850.5
October 293.83 9108.82
November 253.88 7616.44
December 184.58 5721.89
Total yearly 132697

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bois-des-Filion solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.67 5817.82
February 255.97 7167.14
March 354.42 10987
April 423.05 12691.5
May 477.55 14804
June 479.87 14396.2
July 498.25 15445.9
August 459.17 14234.2
September 363.67 10910.1
October 244.7 7585.57
November 187.83 5634.98
December 128.46 3982.38
Total yearly 123657

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 207.24 6424.35
February 273.56 7659.64
March 367.98 11407.5
April 429.14 12874.2
May 477.14 14791.3
June 476.6 14298
July 495.84 15371
August 463.18 14358.6
September 374.59 11237.8
October 258.25 8005.63
November 204.7 6140.96
December 142.52 4418.11
Total yearly 126987

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 224.99 6974.68
February 289.14 8096.02
March 379.29 11758.1
April 432.91 12987.3
May 474.25 14701.8
June 470.74 14122.2
July 490.91 15218.1
August 464.72 14406.5
September 383.26 11497.7
October 270.07 8372.02
November 219.9 6596.93
December 155.3 4814.42
Total yearly 129546

Bois-des-Filion Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 240.88 7467.33
February 302.69 8475.36
March 388.3 12037.4
April 434.34 13030.1
May 468.98 14538.3
June 462.6 13878.1
July 483.51 14988.9
August 463.79 14377.6
September 389.63 11688.9
October 280.11 8683.56
November 233.39 7001.84
December 166.78 5170.27
Total yearly 131338

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.75% angle of incidence loss and -3.82% temperature and irradiance loss. This totals to about -15.82%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Lynn LakeSainte-Agn�s-de-DundeeHighwaterAthelstanSaint-Antoine-Abb�L'�le-aux-NoixWest BromeBolton CentreSabrevoisKnowltonKatevaleAdamsvilleFosterCherry RiverShefford-OuestSaint-Philippe-de-La PrairieSainte-Justine-StationSaddlebrookSaint-Pascal-BaylonOld ChelseaAngersGreenlayPointe-FortuneSaint-Beno�tSaint-HermasMurdochville