Solar Calculator Canada

Solar Power Calculator for Brownsburg-Chatham, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Brownsburg-Chatham
  • GPS Coordinates: 45.67631, -74.408125
  • Elevation: 112 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Brownsburg-Chatham: 39o
  • Average yearly irradiance: 1548.52 kWh/m2
  • Average yearly power output: 129973 kWh
Sun Path Brownsburg-Chatham

Average yearly irradiance delivered by the Sun in Brownsburg-Chatham is 1548.52/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 129973 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.91 90.26
February 3.67 102.86
March 4.72 146.28
April 5.03 150.89
May 5.35 165.85
June 5.36 160.9
July 5.67 175.82
August 5.48 169.98
September 4.67 140.04
October 3.3 102.18
November 2.73 81.83
December 1.99 61.61
Total yearly 1548.52

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 273.01 8463.2
February 340.46 9533.01
March 420.44 13033.8
April 425.15 12754.4
May 434.51 13469.7
June 425.63 12768.9
July 445.71 13816.9
August 434.94 13483.2
September 376.76 11302.8
October 276.91 8584.28
November 238.5 7154.91
December 180.91 5608.35
Total yearly 129973

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Brownsburg-Chatham solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 192.72 5974.38
February 268.84 7527.6
March 371.65 11521.2
April 417.62 12528.6
May 459.31 14238.5
June 464.57 13937.1
July 480.61 14898.8
August 440.31 13649.6
September 348.48 10454.3
October 231.81 7186.09
November 177.21 5316.23
December 126.13 3909.89
Total yearly 121142

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 212.98 6602.25
February 287.73 8056.31
March 386.38 11977.7
April 423.49 12704.6
May 458.46 14212.2
June 460.88 13826.3
July 477.91 14815.2
August 443.64 13752.8
September 358.51 10755.2
October 244.28 7572.8
November 192.85 5785.49
December 139.84 4334.96
Total yearly 124396

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 231.34 7171.51
February 304.48 8525.51
March 398.69 12359.5
April 427.07 12812
May 455.31 14114.7
June 454.76 13642.9
July 472.85 14658.2
August 444.65 13784
September 366.41 10992.2
October 255.14 7909.33
November 206.93 6207.81
December 152.28 4720.77
Total yearly 126899

Brownsburg-Chatham Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 247.77 7680.83
February 319.08 8934.19
March 408.56 12665.5
April 428.35 12850.5
May 449.92 13947.4
June 446.48 13394.5
July 465.46 14429.3
August 443.33 13743.2
September 372.15 11164.6
October 264.34 8194.63
November 219.41 6582.24
December 163.44 5066.52
Total yearly 128653

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.81% angle of incidence loss and -4.04% temperature and irradiance loss. This totals to about -16.07%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Lynn LakeSainte-Agn�s-de-DundeeHighwaterAthelstanSaint-Antoine-Abb�L'�le-aux-NoixWest BromeBolton CentreSabrevoisKnowltonKatevaleAdamsvilleFosterCherry RiverShefford-OuestSaint-Philippe-de-La PrairieSainte-Justine-StationSaddlebrookSaint-Pascal-BaylonOld ChelseaAngersGreenlayPointe-FortuneSaint-Beno�tSaint-HermasMurdochville