Solar Calculator Canada

Solar Power Calculator for Disraeli, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Disraeli
  • GPS Coordinates: 45.902825, -71.357972
  • Elevation: 253 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Disraeli: 39o
  • Average yearly irradiance: 1459.73 kWh/m2
  • Average yearly power output: 123347 kWh
Sun Path Disraeli

Average yearly irradiance delivered by the Sun in Disraeli is 1459.73/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 123347 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.69 83.48
February 3.17 88.75
March 4.2 130.06
April 4.7 141.14
May 5.11 158.37
June 5.23 157
July 5.59 173.38
August 5.26 162.91
September 4.51 135.36
October 3.23 100.2
November 2.47 73.97
December 1.78 55.12
Total yearly 1459.73

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 254.79 7898.39
February 295.41 8271.43
March 376.15 11660.8
April 401.85 12055.5
May 419.99 13019.7
June 420.01 12600.4
July 444.45 13778.1
August 420.61 13038.8
September 367.09 11012.6
October 273.82 8488.44
November 216.37 6490.96
December 162.34 5032.4
Total yearly 123347

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Disraeli solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.84 5637.05
February 237.22 6642.03
March 335.44 10398.6
April 395.33 11859.8
May 441.66 13691.5
June 454.85 13645.4
July 474.98 14724.3
August 425.04 13176.2
September 339.9 10197
October 230.02 7130.59
November 162.34 4870.2
December 113.74 3525.9
Total yearly 115498

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 200.66 6220.41
February 252.96 7082.96
March 348.14 10792.5
April 400.61 12018.3
May 440.87 13667.1
June 450.9 13526.9
July 472.72 14654.2
August 428.13 13272
September 349.65 10489.6
October 242.36 7513.21
November 176.5 5294.87
December 126.18 3911.57
Total yearly 118444

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 217.73 6749.78
February 266.9 7473.11
March 358.7 11119.8
April 403.79 12113.6
May 437.94 13576.2
June 445.38 13361.3
July 467.94 14506.2
August 429.01 13299.3
September 357.33 10719.8
October 253.1 7846.11
November 189.23 5676.9
December 137.51 4262.71
Total yearly 120705

Disraeli Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 233.02 7223.66
February 278.98 7811.51
March 367.09 11379.9
April 404.96 12148.8
May 432.86 13418.6
June 437.42 13122.7
July 460.87 14287.1
August 427.7 13258.6
September 362.89 10886.7
October 262.2 8128.19
November 200.51 6015.42
December 147.68 4578.08
Total yearly 122259

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.91% angle of incidence loss and -3.3% temperature and irradiance loss. This totals to about -15.5%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: