Solar Calculator Canada

Solar Power Calculator for Lac-Saint-Joseph, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Lac-Saint-Joseph
  • GPS Coordinates: 46.914172, -71.662702
  • Elevation: 170 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Lac-Saint-Joseph: 40o
  • Average yearly irradiance: 1482.61 kWh/m2
  • Average yearly power output: 125718 kWh
Sun Path Lac-Saint-Joseph

Average yearly irradiance delivered by the Sun in Lac-Saint-Joseph is 1482.61/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 125718 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.85 88.43
February 3.62 101.39
March 4.52 140.1
April 4.72 141.71
May 5.21 161.5
June 5.24 157.27
July 5.49 170.31
August 5.15 159.76
September 4.38 131.55
October 3.11 96.45
November 2.34 70.11
December 2.07 64.03
Total yearly 1482.61

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 271.33 8411.09
February 339.2 9497.56
March 406.09 12588.9
April 403.84 12115.1
May 427.84 13263
June 419.93 12597.9
July 435.25 13492.9
August 411.54 12757.8
September 356.75 10702.6
October 264.08 8186.47
November 206.01 6180.15
December 191.1 5924.15
Total yearly 125718

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Lac-Saint-Joseph solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.54 5813.82
February 263.99 7391.82
March 356.31 11045.5
April 396.64 11899.1
May 450.84 13976
June 457.93 13737.9
July 466.89 14473.5
August 416.03 12897
September 328.61 9858.23
October 219.43 6802.44
November 151.23 4537.01
December 127.58 3954.99
Total yearly 116387

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 207.89 6444.5
February 283.12 7927.28
March 370.89 11497.7
April 402.38 12071.3
May 450.58 13967.9
June 454.34 13630.1
July 465.11 14418.4
August 419.54 13005.8
September 338.51 10155.3
October 231.52 7177.17
November 164.89 4946.62
December 142.98 4432.39
Total yearly 119674

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 226.34 7016.54
February 300.12 8403.48
March 383.16 11877.9
April 405.95 12178.6
May 448.1 13891.2
June 449.16 13474.8
July 460.83 14285.6
August 420.85 13046.4
September 346.38 10391.5
October 242.06 7503.99
November 177.19 5315.64
December 157.04 4868.23
Total yearly 122254

Lac-Saint-Joseph Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 242.87 7528.97
February 314.98 8819.46
March 393.06 12184.9
April 407.35 12220.6
May 443.34 13743.6
June 441.49 13244.8
July 454.26 14082
August 419.97 13019
September 352.2 10566.1
October 251.03 7781.94
November 188.11 5643.28
December 169.72 5261.18
Total yearly 124096

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.83% angle of incidence loss and -3.04% temperature and irradiance loss. This totals to about -15.21%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: