The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Mirabel
  • GPS Coordinates: 45.663608, -74.002069
  • Elevation: 72 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Mirabel: 39o
  • Average yearly irradiance: 1538.17 kWh/m2
  • Average yearly power output: 128929 kWh
Sun Path Mirabel

Average yearly irradiance delivered by the Sun in Mirabel is 1538.17/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 128929 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.64 81.83
February 3.24 90.61
March 4.27 132.38
April 5.01 150.3
May 5.51 170.84
June 5.49 164.83
July 5.82 180.46
August 5.65 175
September 4.81 144.34
October 3.35 103.88
November 2.8 83.89
December 1.93 59.79
Total yearly 1538.17

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 246.45 7639.88
February 298.14 8347.83
March 379.01 11749.3
April 424.3 12729.1
May 449.37 13930.6
June 437.68 13130.5
July 459.01 14229.2
August 449.23 13926
September 389.35 11680.5
October 282.72 8764.42
November 245.41 7362.3
December 175.47 5439.49
Total yearly 128929

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Mirabel solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 175.08 5427.4
February 237.28 6643.93
March 337.13 10451.1
April 416.63 12499
May 472.22 14639
June 474.24 14227.1
July 491.85 15247.3
August 452.27 14020.4
September 359.07 10772.2
October 236.9 7343.94
November 182.63 5478.83
December 122.11 3785.38
Total yearly 120535

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 193.41 5995.72
February 253.66 7102.59
March 350.04 10851.4
April 422.41 12672.4
May 471.7 14622.7
June 470.86 14125.9
July 489.43 15172.2
August 456.09 14138.8
September 369.7 11091
October 249.74 7742.05
November 198.92 5967.57
December 135.64 4204.91
Total yearly 123687

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 210.03 6510.94
February 268.17 7508.62
March 360.79 11184.4
April 425.92 12777.6
May 468.76 14531.7
June 464.98 13949.4
July 484.55 15021.1
August 457.5 14182.6
September 378.11 11343.3
October 260.93 8088.87
November 213.59 6407.76
December 147.95 4586.33
Total yearly 126093

Mirabel Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 224.9 6971.75
February 280.76 7861.27
March 369.33 11449.1
April 427.14 12814.2
May 463.48 14367.8
June 456.85 13705.6
July 477.27 14795.4
August 456.51 14151.7
September 384.28 11528.3
October 270.43 8383.26
November 226.61 6798.4
December 158.99 4928.68
Total yearly 127756

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.78% angle of incidence loss and -4.2% temperature and irradiance loss. This totals to about -16.18%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Blue MountainsWasaga BeachSouth Bruce PeninsulaPenetanguisheneAbercornBerwickHemmingfordSaint AndrewsWolfvilleSt. GeorgeCarleton PlaceAyer's CliffBromeMississippi MillsNorth HatleyStukely-SudGrand Bay-WestfieldRothesayLawrencevilleQuispamsisWestvilleStellartonRoxton FallsSainte-MadeleineTrentonMurdochville