Solar Calculator Canada

Solar Power Calculator for Saint-Eugène-de-Grantham, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Saint-Eugène-de-Grantham
  • GPS Coordinates: 45.8044444, -72.6983333
  • Elevation: 75 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Saint-Eugène-de-Grantham: 39o
  • Average yearly irradiance: 1536.33 kWh/m2
  • Average yearly power output: 129292 kWh
Sun Path Saint-Eug%C3%A8ne-de-Grantham

Average yearly irradiance delivered by the Sun in Saint-Eugène-de-Grantham is 1536.33/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 129292 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.83 87.66
February 3.37 94.23
March 4.37 135.62
April 4.95 148.45
May 5.41 167.74
June 5.44 163.33
July 5.83 180.83
August 5.45 168.95
September 4.69 140.61
October 3.4 105.47
November 2.75 82.59
December 1.96 60.86
Total yearly 1536.33

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 265.77 8238.75
February 311.73 8728.54
March 389.51 12074.8
April 419.36 12580.9
May 442.27 13710.4
June 434.92 13047.5
July 461.44 14304.7
August 434.28 13462.5
September 380.45 11413.6
October 287.8 8921.93
November 241.78 7253.37
December 179.2 5555.09
Total yearly 129292

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Saint-Eugène-de-Grantham solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 186.52 5782.22
February 246.55 6903.5
March 344.96 10693.7
April 411.53 12345.9
May 465.63 14434.6
June 472.94 14188.3
July 494.41 15326.9
August 438.86 13604.7
September 351.29 10538.7
October 239.97 7439.11
November 178.7 5361.03
December 123.43 3826.29
Total yearly 120445

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.47 6400.54
February 263.8 7386.52
March 358.51 11113.7
April 417.42 12522.7
May 465.22 14421.7
June 469.43 14083
July 492.28 15260.8
August 442.37 13713.3
September 361.55 10846.6
October 253.12 7846.75
November 194.79 5843.82
December 137.36 4258.31
Total yearly 123698

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 224.58 6961.91
February 279.1 7814.71
March 369.82 11464.3
April 421.06 12631.8
May 462.38 14333.6
June 463.44 13903.2
July 487.59 15115.2
August 443.56 13750.3
September 369.67 11090
October 264.58 8202.08
November 209.29 6278.58
December 150.05 4651.61
Total yearly 126197

Saint-Eugène-de-Grantham Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 240.8 7464.85
February 292.4 8187.23
March 378.85 11744.4
April 422.42 12672.7
May 457.24 14174.5
June 455.23 13656.9
July 480.45 14894
August 442.43 13715.5
September 375.61 11268.4
October 274.32 8503.93
November 222.15 6664.42
December 161.46 5005.13
Total yearly 127952

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.79% angle of incidence loss and -3.81% temperature and irradiance loss. This totals to about -15.84%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: