Solar Calculator Canada

Solar Power Calculator for Terrebonne, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Terrebonne
  • GPS Coordinates: 45.691538, -73.634302
  • Elevation: 7 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Terrebonne: 39o
  • Average yearly irradiance: 1546.47 kWh/m2
  • Average yearly power output: 130261 kWh
Sun Path Terrebonne

Average yearly irradiance delivered by the Sun in Terrebonne is 1546.47/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 130261 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.82 87.28
February 3.49 97.73
March 4.36 135.06
April 4.99 149.67
May 5.42 167.93
June 5.44 163.09
July 5.75 178.24
August 5.56 172.46
September 4.79 143.62
October 3.39 105.11
November 2.84 85.12
December 1.97 61.17
Total yearly 1546.47

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 264.13 8187.97
February 323.92 9069.64
March 389.23 12066
April 423.89 12716.8
May 443.13 13737.2
June 434.04 13021.1
July 454.36 14085.2
August 443.41 13745.7
September 388.55 11656.5
October 286.97 8896.1
November 249.83 7494.79
December 180.11 5583.55
Total yearly 130261

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Terrebonne solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 186.09 5768.85
February 256.29 7176.22
March 346.2 10732.2
April 416.76 12502.9
May 467.38 14488.8
June 471.86 14155.9
July 488.81 15153
August 447.85 13883.5
September 357.98 10739.5
October 239.36 7420.29
November 184.58 5537.32
December 125.08 3877.42
Total yearly 121436

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 205.63 6374.57
February 274.1 7674.86
March 359.33 11139.3
April 422.66 12679.9
May 466.95 14475.5
June 468.64 14059.2
July 486.42 15079.1
August 451.59 13999.1
September 368.58 11057.4
October 252.42 7824.97
November 201.15 6034.39
December 138.78 4302.22
Total yearly 124700

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 223.36 6924.17
February 289.89 8116.87
March 370.27 11478.4
April 426.29 12788.6
May 464.12 14387.6
June 462.91 13887.2
July 481.58 14929.1
August 452.93 14041
September 376.97 11309
October 263.8 8177.75
November 216.08 6482.5
December 151.25 4688.7
Total yearly 127211

Terrebonne Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 239.23 7416.21
February 303.62 8501.35
March 378.98 11748.3
April 427.62 12828.5
May 458.96 14227.8
June 454.95 13648.5
July 474.36 14705.1
August 451.9 14008.8
September 383.12 11493.5
October 273.47 8477.43
November 229.35 6880.54
December 162.44 5035.79
Total yearly 128972

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.77% angle of incidence loss and -3.74% temperature and irradiance loss. This totals to about -15.77%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Blue MountainsWasaga BeachSouth Bruce PeninsulaPenetanguisheneAbercornBerwickHemmingfordSaint AndrewsWolfvilleSt. GeorgeCarleton PlaceAyer's CliffBromeMississippi MillsNorth HatleyStukely-SudGrand Bay-WestfieldRothesayLawrencevilleQuispamsisWestvilleStellartonRoxton FallsSainte-MadeleineTrentonMurdochville