Solar Calculator Canada

Solar Power Calculator for Davidson, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Davidson
  • GPS Coordinates: 51.2591611, -105.9859314
  • Elevation: 618 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Davidson: 43o
  • Average yearly irradiance: 1513.85 kWh/m2
  • Average yearly power output: 128983 kWh
Sun Path Davidson

Average yearly irradiance delivered by the Sun in Davidson is 1513.85/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 128983 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.89 58.46
February 2.63 73.71
March 3.59 111.36
April 5.34 160.21
May 5.79 179.46
June 5.66 169.92
July 6.47 200.56
August 5.82 180.39
September 5 150.05
October 3.67 113.81
November 2.14 64.06
December 1.67 51.87
Total yearly 1513.85

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.03 5611.91
February 249.8 6994.51
March 324.47 10058.4
April 461.28 13838.3
May 483.77 14997
June 460.05 13801.6
July 518.98 16088.5
August 469.28 14547.6
September 415.29 12458.6
October 317.91 9855.34
November 193.26 5797.82
December 159.13 4932.98
Total yearly 128983

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Davidson solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 110.9 3437.99
February 176.08 4930.27
March 270.36 8381.26
April 436.53 13096
May 501.86 15557.5
June 497.19 14915.8
July 551.36 17092.2
August 462.75 14345.1
September 362.68 10880.4
October 242.72 7524.46
November 128 3839.93
December 92.07 2854.22
Total yearly 116855

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 126.65 3926.11
February 193.58 5420.22
March 284.85 8830.24
April 446.7 13400.9
May 504.45 15637.8
June 495.89 14876.8
July 552.04 17113.3
August 469.88 14566.3
September 377.78 11333.5
October 260.95 8089.59
November 142.77 4283.15
December 106.97 3316.15
Total yearly 120794

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 141.08 4373.53
February 209.38 5862.73
March 297.34 9217.61
April 454.28 13628.3
May 504.06 15625.7
June 492.24 14767.1
July 550.16 17055
August 474.3 14703.4
September 390.44 11713.3
October 277.23 8594.03
November 156.25 4687.39
December 120.67 3740.89
Total yearly 123969

Davidson Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 154.17 4779.18
February 223.46 6256.91
March 307.83 9542.65
April 459.25 13777.5
May 500.99 15530.7
June 485.7 14571
July 544.94 16893.2
August 476.08 14758.5
September 400.61 12018.4
October 291.49 9036.29
November 168.38 5051.44
December 133.14 4127.22
Total yearly 126343

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.7% angle of incidence loss and -2.71% temperature and irradiance loss. This totals to about -14.8%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: