Solar Calculator Canada

Solar Power Calculator for Drinkwater, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Drinkwater
  • GPS Coordinates: 50.2949361, -105.1337967
  • Elevation: 570 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Drinkwater: 42o
  • Average yearly irradiance: 1516.17 kWh/m2
  • Average yearly power output: 128155 kWh
Sun Path Drinkwater

Average yearly irradiance delivered by the Sun in Drinkwater is 1516.17/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 128155 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2 61.9
February 2.7 75.49
March 3.6 111.7
April 5.3 159.02
May 5.6 173.6
June 5.71 171.28
July 6.43 199.43
August 5.85 181.3
September 5.06 151.73
October 3.65 113.15
November 2.25 67.52
December 1.61 50.04
Total yearly 1516.17

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 189.45 5872.95
February 252.35 7065.88
March 320.66 9940.49
April 454.17 13625
May 465.23 14422.2
June 461.61 13848.4
July 512.63 15891.5
August 467.75 14500.1
September 416.73 12501.9
October 313.78 9727.04
November 202.21 6066.29
December 151.39 4692.99
Total yearly 128155

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Drinkwater solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 120.08 3722.38
February 182.91 5121.56
March 272.94 8461.07
April 431.97 12959.2
May 483.92 15001.7
June 499.7 14991
July 544.67 16884.7
August 462.84 14348
September 367.48 11024.5
October 243.17 7538.13
November 136.7 4100.96
December 91.5 2836.56
Total yearly 116990

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 136.24 4223.29
February 199.88 5596.59
March 286.22 8872.94
April 441.49 13244.6
May 485.57 15052.6
June 497.99 14939.8
July 544.94 16893.1
August 469.4 14551.3
September 382.06 11461.8
October 260.67 8080.82
November 151.99 4559.59
December 105.27 3263.3
Total yearly 120740

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 151 4680.85
February 215.15 6024.09
March 297.59 9225.44
April 448.47 13454.2
May 484.45 15018
June 493.56 14806.7
July 542.29 16811.1
August 473.31 14672.7
September 394.19 11825.7
October 276.25 8563.66
November 165.91 4977.24
December 117.89 3654.46
Total yearly 123714

Drinkwater Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 164.33 5094.25
February 228.69 6403.31
March 307.02 9517.74
April 452.9 13587.1
May 480.82 14905.3
June 486.38 14591.5
July 536.52 16632
August 474.61 14712.9
September 403.84 12115.2
October 289.85 8985.24
November 178.42 5352.74
December 129.33 4009.17
Total yearly 125906

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -3.46% temperature and irradiance loss. This totals to about -15.47%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville