Solar Calculator Canada

Solar Power Calculator for Kindersley, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Kindersley
  • GPS Coordinates: 51.4676781, -109.1566139
  • Elevation: 686 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Kindersley: 43o
  • Average yearly irradiance: 1521.27 kWh/m2
  • Average yearly power output: 128536 kWh
Sun Path Kindersley

Average yearly irradiance delivered by the Sun in Kindersley is 1521.27/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 128536 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.81 55.99
February 2.64 73.84
March 3.69 114.44
April 5.28 158.39
May 5.83 180.62
June 5.64 169.08
July 6.49 201.29
August 5.94 184.16
September 5.05 151.6
October 3.78 117.29
November 2.25 67.49
December 1.52 47.07
Total yearly 1521.27

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 170.16 5274.88
February 244.6 6848.82
March 327.25 10144.8
April 452.94 13588.3
May 484.86 15030.8
June 455.88 13676.5
July 517.62 16046.3
August 476.71 14777.9
September 417 12509.9
October 326.45 10120
November 203.27 6098.14
December 142.56 4419.51
Total yearly 128536

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Kindersley solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 103.92 3221.46
February 172.81 4838.66
March 273.84 8488.94
April 430.21 12906.2
May 504.69 15645.5
June 496.13 14883.8
July 549.15 17023.6
August 468.13 14511.9
September 363.32 10899.6
October 247.67 7677.66
November 133.43 4002.93
December 83.64 2592.92
Total yearly 116693

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 118.53 3674.41
February 189.45 5304.63
March 287.91 8925.19
April 440.09 13202.6
May 507.11 15720.5
June 494.05 14821.5
July 549.6 17037.6
August 475.81 14750
September 378.56 11356.8
October 266.39 8258.18
November 149.03 4470.98
December 96.55 2992.98
Total yearly 120515

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.93 4089.97
February 204.45 5724.58
March 300.04 9301.38
April 447.48 13424.4
May 507.09 15719.9
June 489.7 14691
July 547.33 16967.3
August 480.92 14908.6
September 391.38 11741.3
October 283.11 8776.54
November 163.28 4898.41
December 108.41 3360.86
Total yearly 123604

Kindersley Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 144.09 4466.86
February 217.78 6097.88
March 310.21 9616.57
April 452.35 13570.6
May 504.32 15633.8
June 483.71 14511.3
July 543.01 16833.4
August 483.39 14985.2
September 401.69 12050.7
October 297.78 9231.25
November 176.13 5283.91
December 119.21 3695.48
Total yearly 125977

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -3.51% temperature and irradiance loss. This totals to about -15.51%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Prince GeorgePrince RupertFlin FlonGrande PrairieThompsonFort St. JohnYarmouthChannel-Port aux BasquesGanderBanffLabrador CityHappy Valley - Goose BayHintonLa RongeHigh LevelChurchillFort Smithnear Watson Lake100km south from Hay RiverDawsonNorman WellsInuvikTorontoOttawaFrederictonMurdochville