Solar Calculator Canada

Solar Power Calculator for Lanigan, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Lanigan
  • GPS Coordinates: 51.8490333, -105.0298972
  • Elevation: 534 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Lanigan: 43o
  • Average yearly irradiance: 1468.81 kWh/m2
  • Average yearly power output: 125024 kWh
Sun Path Lanigan

Average yearly irradiance delivered by the Sun in Lanigan is 1468.81/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 125024 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.76 54.45
February 2.6 72.92
March 3.53 109.52
April 5.18 155.43
May 5.83 180.69
June 5.55 166.55
July 6.2 192.21
August 5.75 178.31
September 4.86 145.69
October 3.4 105.31
November 1.99 59.67
December 1.55 48.05
Total yearly 1468.81

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 168.89 5235.54
February 247.12 6919.42
March 318.33 9868.34
April 446.46 13393.7
May 486.31 15075.7
June 450.24 13507.3
July 497.09 15409.7
August 464.04 14385.2
September 403.5 12104.9
October 294.3 9123.29
November 180.31 5409.33
December 148.12 4591.64
Total yearly 125024

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Lanigan solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 102.62 3181.17
February 173.38 4854.58
March 265.4 8227.39
April 421.66 12649.8
May 503.22 15599.8
June 486.21 14586.3
July 527.77 16361
August 456.15 14140.8
September 351.27 10538.1
October 223.78 6937.1
November 118.33 3550.05
December 85.37 2646.4
Total yearly 113273

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 117.48 3641.83
February 190.76 5341.4
March 279.71 8670.93
April 431.62 12948.7
May 506.2 15692.3
June 484.62 14538.5
July 528.54 16384.9
August 463.5 14368.4
September 366.01 10980.4
October 240.77 7463.83
November 132.34 3970.14
December 99.19 3074.77
Total yearly 117076

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.1 4064.01
February 206.47 5781.11
March 292.06 9053.9
April 439.09 13172.6
May 506.17 15691.2
June 481.56 14446.8
July 526.69 16327.5
August 468.18 14513.6
September 378.39 11351.8
October 255.96 7934.63
November 145.12 4353.62
December 111.92 3469.66
Total yearly 120160

Lanigan Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 143.44 4446.73
February 220.46 6172.93
March 302.44 9375.6
April 444.03 13320.9
May 503.4 15605.4
June 475.33 14259.8
July 521.67 16171.7
August 470.24 14577.6
September 388.37 11651
October 269.29 8347.99
November 156.64 4699.31
December 123.54 3829.64
Total yearly 122459

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.73% angle of incidence loss and -2.77% temperature and irradiance loss. This totals to about -14.88%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

CharlottetownQuebecSt. John'sVictoriaWinnipegReginaEdmontonIqaluitFort SevernKangirsukFort NelsonNainZama CityWollaston LakeFond-du-LacBlack LakeWollaston LakeHalifaxMurray RiverTofinoMurdochville