Solar Calculator Canada

Solar Power Calculator for Shellbrook, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Shellbrook
  • GPS Coordinates: 53.2203306, -106.3885444
  • Elevation: 499 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Shellbrook: 44o
  • Average yearly irradiance: 1416 kWh/m2
  • Average yearly power output: 119960 kWh
Sun Path Shellbrook

Average yearly irradiance delivered by the Sun in Shellbrook is 1416/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 119960 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.53 47.52
February 2.52 70.47
March 3.79 117.34
April 5.11 153.34
May 5.82 180.51
June 5.37 161.2
July 5.99 185.76
August 5.5 170.47
September 4.5 135.12
October 3.3 102.18
November 1.66 49.81
December 1.36 42.29
Total yearly 1416

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 145.97 4525.08
February 236.49 6621.61
March 340.48 10554.8
April 439.21 13176.2
May 484.06 15005.8
June 434.03 13020.8
July 478.35 14828.9
August 442.88 13729.2
September 372.46 11173.7
October 284.61 8822.88
November 149.84 4495.2
December 129.22 4005.8
Total yearly 119960

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Shellbrook solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 87.2 2703.22
February 164.84 4615.59
March 280.02 8680.51
April 413.22 12396.6
May 498.05 15439.5
June 468.27 14048.2
July 506 15686.2
August 433.65 13443
September 323.3 9698.87
October 213.45 6616.91
November 96.33 2889.95
December 72.08 2234.47
Total yearly 108453

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 100.17 3105.24
February 181.53 5082.75
March 295.91 9173.29
April 423.47 12704.2
May 501.5 15546.4
June 467.22 14016.6
July 506.88 15713.2
August 440.89 13667.6
September 337.11 10113.2
October 230.48 7144.76
November 108.25 3247.39
December 84.54 2620.61
Total yearly 112135

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 112.06 3473.96
February 196.59 5504.52
March 309.71 9600.91
April 431.27 12938
May 502.07 15564.3
June 463.98 13919.5
July 505.32 15664.9
August 445.64 13814.8
September 348.75 10462.5
October 245.73 7617.69
November 119.13 3574.05
December 96.04 2977.2
Total yearly 115112

Shellbrook Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 122.85 3808.38
February 210.01 5880.28
March 321.38 9962.82
April 436.59 13097.8
May 499.9 15496.8
June 458.56 13756.8
July 501.36 15542.1
August 447.9 13884.9
September 358.19 10745.7
October 259.17 8034.32
November 128.96 3868.92
December 106.54 3302.63
Total yearly 117381

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.79% angle of incidence loss and -3.17% temperature and irradiance loss. This totals to about -15.28%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: