Solar Calculator Canada

Solar Power Calculator for Tisdale, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Tisdale
  • GPS Coordinates: 52.84905, -104.0490972
  • Elevation: 451 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Tisdale: 43o
  • Average yearly irradiance: 1458.45 kWh/m2
  • Average yearly power output: 124393 kWh
Sun Path Tisdale

Average yearly irradiance delivered by the Sun in Tisdale is 1458.45/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 124393 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.69 52.28
February 2.61 73.21
March 3.6 111.54
April 5.23 157.03
May 5.89 182.7
June 5.61 168.21
July 6.1 189.04
August 5.78 179.24
September 4.66 139.75
October 3.43 106.48
November 1.77 53.15
December 1.48 45.81
Total yearly 1458.45

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 164.04 5085.38
February 249.96 6998.9
March 326.46 10120.2
April 451.7 13551
May 491.6 15239.5
June 454.91 13647.4
July 489.57 15176.8
August 467.37 14488.3
September 387.06 11611.9
October 298.44 9251.65
November 161.14 4834.35
December 141.52 4387.06
Total yearly 124393

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Tisdale solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 98.63 3057.43
February 173.19 4849.18
March 266.69 8267.54
April 425.31 12759.2
May 510.67 15830.8
June 492.66 14779.8
July 518.45 16071.8
August 457.84 14193
September 336.18 10085.4
October 223.26 6920.98
November 103.59 3107.79
December 81.09 2513.8
Total yearly 112437

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 112.94 3501.28
February 190.63 5337.54
March 281.92 8739.54
April 435.93 13077.9
May 513.78 15927.2
June 491.19 14735.7
July 519.48 16103.8
August 465.55 14432
September 350.46 10513.8
October 240.77 7464.02
November 116.26 3487.89
December 94.24 2921.41
Total yearly 116242

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 126.06 3907.91
February 206.38 5778.55
March 295.14 9149.43
April 444.01 13320.2
May 514.18 15939.5
June 488.38 14651.5
July 518.19 16063.8
August 470.6 14588.7
September 362.48 10874.5
October 256.46 7950.2
November 127.84 3835.22
December 106.35 3296.76
Total yearly 119356

Tisdale Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 137.95 4276.49
February 220.41 6171.53
March 306.34 9496.51
April 449.52 13485.6
May 511.66 15861.5
June 482.36 14470.8
July 513.67 15923.7
August 473.02 14663.6
September 372.21 11166.3
October 270.26 8378.06
November 138.29 4148.67
December 117.38 3638.69
Total yearly 121681

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.75% angle of incidence loss and -2.55% temperature and irradiance loss. This totals to about -14.71%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: