Solar Calculator Canada

Solar Power Calculator for Whitewood, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Whitewood
  • GPS Coordinates: 50.3311528, -102.2698528
  • Elevation: 603 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Whitewood: 43o
  • Average yearly irradiance: 1561.31 kWh/m2
  • Average yearly power output: 133309 kWh
Sun Path Whitewood

Average yearly irradiance delivered by the Sun in Whitewood is 1561.31/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 133309 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.13 66.07
February 3.08 86.14
March 3.79 117.43
April 5.48 164.43
May 5.66 175.54
June 5.63 168.78
July 6.46 200.2
August 5.83 180.69
September 5.16 154.73
October 3.78 117.27
November 2.42 72.46
December 1.86 57.59
Total yearly 1561.31

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 205.05 6356.54
February 292 8176.02
March 341.13 10575
April 472.74 14182.2
May 472.99 14662.6
June 456.32 13689.7
July 517.56 16044.3
August 469.94 14568.1
September 427.84 12835.3
October 328.2 10174.2
November 219.41 6582.41
December 176.21 5462.48
Total yearly 133309

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Whitewood solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 129.46 4013.25
February 209.03 5852.77
March 287.42 8909.88
April 451.83 13554.9
May 495.92 15373.6
June 498.7 14960.9
July 552.44 17125.5
August 466.85 14472.4
September 376.55 11296.4
October 252.26 7820.1
November 146.44 4393.18
December 105.67 3275.74
Total yearly 121049

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 146.44 4539.62
February 228.39 6394.84
March 301.68 9352.13
April 461.8 13854.1
May 497.47 15421.6
June 496.37 14891.1
July 552.82 17137.6
August 473.38 14674.8
September 391.59 11747.8
October 270.58 8387.89
November 163.03 4890.78
December 121.33 3761.37
Total yearly 125054

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 161.94 5020.21
February 245.79 6882.18
March 313.91 9731.12
April 469.12 14073.5
May 496.67 15396.7
June 492.04 14761.1
July 550.18 17055.7
August 477.29 14795.8
September 404.13 12123.9
October 286.89 8893.5
November 178.12 5343.61
December 135.69 4206.52
Total yearly 128284

Whitewood Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 175.94 5454.2
February 261.22 7314.06
March 324.06 10046
April 473.74 14212.3
May 493.11 15286.4
June 484.86 14545.7
July 544.4 16876.6
August 478.55 14835.2
September 414.13 12423.8
October 301.14 9335.35
November 191.68 5750.52
December 148.71 4610.07
Total yearly 130690

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.7% angle of incidence loss and -2.5% temperature and irradiance loss. This totals to about -14.62%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: