Solar Calculator Canada

Solar Power Calculator for Acme, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Acme
  • GPS Coordinates: 51.4972222, -113.5086111
  • Elevation: 903 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Acme: 42o
  • Average yearly irradiance: 1509.05 kWh/m2
  • Average yearly power output: 126242 kWh
Sun Path Acme

Average yearly irradiance delivered by the Sun in Acme is 1509.05/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 126242 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.83 56.58
February 2.63 73.63
March 3.54 109.69
April 5.09 152.75
May 5.85 181.31
June 5.74 172.1
July 6.49 201.26
August 5.85 181.26
September 4.96 148.73
October 3.66 113.54
November 2.36 70.74
December 1.53 47.45
Total yearly 1509.05

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 166.51 5161.8
February 236.42 6619.85
March 307.49 9532.26
April 433.04 12991.3
May 482.71 14964
June 463.51 13905.3
July 515.62 15984.3
August 466.97 14476.1
September 406.69 12200.6
October 313.23 9710.15
November 211.29 6338.83
December 140.56 4357.36
Total yearly 126242

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Acme solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 105.04 3256.1
February 170.36 4770.16
March 258.82 8023.4
April 413.14 12394.3
May 499.7 15490.8
June 499.87 14996
July 544.38 16875.7
August 457.75 14190.4
September 356.58 10697.4
October 240.23 7447.16
November 138.64 4159.07
December 83.85 2599.5
Total yearly 114900

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.09 3691.87
February 186.09 5210.48
March 271.9 8428.76
April 422.08 12662.3
May 501.74 15553.9
June 497.93 14937.9
July 544.8 16888.8
August 465.18 14420.5
September 371.15 11134.6
October 258.04 7999.12
November 155.3 4659.1
December 96.67 2996.66
Total yearly 118584

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.94 4090.07
February 200.24 5606.59
March 283.16 8777.81
April 428.74 12862.3
May 501.37 15542.6
June 493.68 14810.5
July 542.64 16821.8
August 470.11 14573.5
September 383.35 11500.4
October 273.91 8491.24
November 170.5 5115.07
December 108.41 3360.77
Total yearly 121553

Acme Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 143.54 4449.88
February 212.78 5957.87
March 292.57 9069.82
April 432.9 12987.1
May 498.93 15466.8
June 487.26 14617.8
July 538.21 16684.5
August 472.33 14642.2
September 393.13 11793.8
October 287.81 8922.21
November 184.2 5525.86
December 119.07 3691.05
Total yearly 123809

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -4.46% temperature and irradiance loss. This totals to about -16.34%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: