Solar Calculator Canada

Solar Power Calculator for Waskatenau, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Waskatenau
  • GPS Coordinates: 54.0938889, -112.7841667
  • Elevation: 634 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Waskatenau: 43o
  • Average yearly irradiance: 1404.4 kWh/m2
  • Average yearly power output: 118656 kWh
Sun Path Waskatenau

Average yearly irradiance delivered by the Sun in Waskatenau is 1404.4/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 118656 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.29 39.95
February 2.24 62.82
March 3.43 106.34
April 5.05 151.47
May 5.85 181.35
June 5.69 170.65
July 6.16 191.07
August 5.56 172.33
September 4.53 135.83
October 3.29 102.02
November 1.83 54.84
December 1.15 35.74
Total yearly 1404.4

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 120.54 3736.63
February 207.13 5799.52
March 306.64 9505.75
April 433.65 13009.5
May 486 15065.9
June 461.41 13842.2
July 494.28 15322.6
August 449.58 13936.9
September 376.17 11285.2
October 285.22 8841.96
November 165.15 4954.53
December 108.23 3355.19
Total yearly 118656

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Waskatenau solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 71.45 2215.05
February 143.1 4006.81
March 250.74 7773.06
April 405.9 12176.9
May 498.69 15459.5
June 494.55 14836.6
July 518.31 16067.7
August 437.79 13571.4
September 324.32 9729.56
October 211.61 6559.96
November 103.35 3100.5
December 60.79 1884.43
Total yearly 107381

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 82.3 2551.16
February 157.85 4419.68
March 265.13 8218.94
April 416.46 12493.7
May 501.82 15556.5
June 493.61 14808.3
July 519.63 16108.5
August 445.45 13809
September 338.61 10158.3
October 228.86 7094.62
November 117.03 3511
December 71.17 2206.22
Total yearly 110936

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 92.26 2859.92
February 171.18 4793.1
March 277.65 8607.1
April 424.72 12741.7
May 502.45 15576.1
June 490.31 14709.4
July 518.37 16069.6
August 450.85 13976.4
September 350.71 10521.2
October 244.36 7575.03
November 129.58 3887.37
December 80.73 2502.57
Total yearly 113819

Waskatenau Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 101.31 3140.47
February 183.09 5126.41
March 288.28 8936.83
April 430.5 12915.1
May 500.76 15523.5
June 484.78 14543.5
July 514.79 15958.4
August 453.79 14067.6
September 360.57 10817.2
October 258.05 7999.56
November 140.94 4228.34
December 89.44 2772.67
Total yearly 116030

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.78% angle of incidence loss and -3.44% temperature and irradiance loss. This totals to about -15.51%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville