Solar Calculator Canada

Solar Power Calculator for Strathmore, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Strathmore
  • GPS Coordinates: 51.0455556, -113.3930556
  • Elevation: 974 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Strathmore: 43o
  • Average yearly irradiance: 1545.27 kWh/m2
  • Average yearly power output: 129294 kWh
Sun Path Strathmore

Average yearly irradiance delivered by the Sun in Strathmore is 1545.27/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 129294 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.97 60.93
February 2.77 77.61
March 3.65 113.29
April 5.14 154.25
May 5.79 179.38
June 5.81 174.18
July 6.6 204.64
August 5.92 183.51
September 5.06 151.78
October 3.76 116.64
November 2.49 74.7
December 1.75 54.36
Total yearly 1545.27

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 179.2 5555.26
February 248.02 6944.43
March 316.74 9818.95
April 437.23 13116.9
May 477.61 14806
June 468.98 14069.4
July 523.93 16241.8
August 472.49 14647.2
September 414.98 12449.5
October 321.68 9971.98
November 222.9 6686.97
December 160.83 4985.61
Total yearly 129294

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Strathmore solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 112.94 3501.15
February 179.36 5022.11
March 267.52 8293.03
April 418.08 12542.5
May 495.8 15369.8
June 507.23 15216.9
July 555.03 17205.8
August 465.04 14416.3
September 364.7 10941
October 246.81 7651.25
November 146.44 4393.35
December 95.66 2965.5
Total yearly 117519

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 128.04 3969.16
February 195.67 5478.7
March 280.77 8703.81
April 426.94 12808.3
May 497.6 15425.7
June 504.96 15148.7
July 555.16 17210.1
August 472.28 14640.6
September 379.43 11383
October 265.08 8217.54
November 163.95 4918.5
December 110.34 3420.58
Total yearly 121325

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 141.83 4396.63
February 210.33 5889.18
March 292.15 9056.77
April 433.51 13005.4
May 497.04 15408.3
June 500.38 15011.3
July 552.69 17133.3
August 476.97 14785.9
September 391.73 11751.8
October 281.36 8722.28
November 179.91 5397.24
December 123.81 3838.22
Total yearly 124396

Strathmore Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 154.28 4782.74
February 223.32 6252.87
March 301.65 9351.14
April 437.54 13126.1
May 494.46 15328.2
June 493.64 14809.2
July 547.9 16985.1
August 478.91 14846.2
September 401.55 12046.6
October 295.62 9164.1
November 194.28 5828.39
December 136.04 4217.3
Total yearly 126738

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -4.44% temperature and irradiance loss. This totals to about -16.33%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Elk PointLegalRedwaterMayerthorpeSmoky LakeCreightonWembleyBeaverlodgeSexsmithMcLennanFalherStanhopeMansonvilleBarnstonWoburnSaint-PaulQuyonSaint-Andr�-EstPerkinsWakefieldSainte-C�cile-de-MashamLac-des-LoupsChapeauColeraineSaint-Prosper-de-DorchesterMurdochville