Solar Calculator Canada

Solar Power Calculator for Creighton, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Creighton
  • GPS Coordinates: 54.75375, -101.898711
  • Elevation: 328 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Creighton: 46o
  • Average yearly irradiance: 1433.88 kWh/m2
  • Average yearly power output: 123324 kWh
Sun Path Creighton

Average yearly irradiance delivered by the Sun in Creighton is 1433.88/kWh/m2 at the optimal panel slope of 46o. After taking all losses into account, you can expect about 123324 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 46o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.96 60.66
February 3.32 92.97
March 4.38 135.77
April 5.36 160.93
May 5.74 177.85
June 5.49 164.71
July 5.45 168.97
August 5.17 160.21
September 4.18 125.26
October 2.92 90.59
November 1.65 49.53
December 1.5 46.44
Total yearly 1433.88

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 191.97 5950.92
February 320.88 8984.5
March 402.94 12491
April 468.85 14065.7
May 479.09 14851.9
June 444.33 13329.9
July 434.06 13455.9
August 416.76 12919.4
September 346.49 10394.8
October 253.36 7854.24
November 150.7 4520.98
December 145.31 4504.5
Total yearly 123324

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Creighton solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 108.44 3361.66
February 214.4 6003.06
March 322.55 9999.06
April 437.42 13122.5
May 499.11 15472.4
June 483.77 14513.2
July 463.81 14378.1
August 410.39 12722.1
September 299.26 8977.82
October 187.18 5802.6
November 93.18 2795.44
December 77.72 2409.25
Total yearly 109557

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 125.52 3891.15
February 237.19 6641.39
March 342.03 10602.9
April 449.49 13484.8
May 502.41 15574.7
June 483.28 14498.3
July 464.94 14413.2
August 417.48 12941.9
September 312.13 9364.01
October 201.95 6260.6
November 105.14 3154.23
December 91.54 2837.6
Total yearly 113665

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 141.22 4377.73
February 257.84 7219.62
March 359.05 11130.5
April 458.85 13765.6
May 503.26 15601
June 480.34 14410.2
July 463.87 14380.1
August 422.18 13087.6
September 323.01 9690.23
October 215.19 6670.97
November 116.09 3482.67
December 104.27 3232.35
Total yearly 117049

Creighton Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 155.49 4820.06
February 276.31 7736.77
March 373.58 11581
April 465.54 13966.1
May 501.8 15555.7
June 475.68 14270.4
July 460.54 14276.8
August 424.56 13161.3
September 331.88 9956.36
October 226.85 7032.48
November 125.99 3779.67
December 115.88 3592.27
Total yearly 119729

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.79% angle of incidence loss and -1.69% temperature and irradiance loss. This totals to about -13.99%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: