Solar Calculator Canada

Solar Power Calculator for Enderby, British Columbia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Enderby
  • GPS Coordinates: 50.550556, -119.139444
  • Elevation: 356 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Enderby: 37o
  • Average yearly irradiance: 1397.4 kWh/m2
  • Average yearly power output: 113007 kWh
Sun Path Enderby

Average yearly irradiance delivered by the Sun in Enderby is 1397.4/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 113007 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.07 33.21
February 2.17 60.8
March 3.41 105.59
April 4.96 148.83
May 5.89 182.7
June 5.72 171.64
July 6.59 204.22
August 6.16 191.05
September 4.64 139.33
October 2.79 86.56
November 1.39 41.69
December 1.02 31.76
Total yearly 1397.4

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 92.19 2857.89
February 188.09 5266.55
March 291.08 9023.33
April 414.26 12427.7
May 473.44 14676.8
June 452.27 13568.2
July 507.02 15717.7
August 477.92 14815.7
September 371.17 11135
October 232.63 7211.43
November 118.42 3552.74
December 88.83 2753.74
Total yearly 113007

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Enderby solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 68.2 2114.09
February 152.5 4269.9
March 259.84 8055.04
April 398.13 11944
May 482.41 14954.8
June 475.2 14256
July 525.29 16284
August 467.88 14504.2
September 335.23 10056.8
October 194.72 6036.23
November 91.05 2731.64
December 62.1 1924.97
Total yearly 107132

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 74.8 2318.68
February 162.9 4561.3
March 269.64 8358.7
April 405.12 12153.6
May 483.98 15003.3
June 473.47 14204
July 525.56 16292.5
August 474.33 14704.3
September 347.27 10418
October 206.18 6391.5
November 98.8 2964.1
December 69.31 2148.72
Total yearly 109519

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 80.74 2502.82
February 172.09 4818.42
March 277.85 8613.28
April 410 12299.9
May 483.07 14975
June 469.69 14090.8
July 522.71 16203.9
August 478.2 14824.2
September 357.18 10715.3
October 216.22 6702.81
November 105.75 3172.48
December 75.85 2351.39
Total yearly 111270

Enderby Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 86.01 2666.34
February 180.04 5041.19
March 284.45 8818.06
April 412.74 12382.2
May 479.72 14871.4
June 463.34 13900.3
July 517.14 16031.5
August 479.49 14864
September 364.94 10948.3
October 224.83 6969.65
November 111.89 3356.59
December 81.7 2532.81
Total yearly 112382

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.88% angle of incidence loss and -7.48% temperature and irradiance loss. This totals to about -19.13%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Lewin's CoveCape BroyleSaint-L�onardGarnishColinetWitless BayRed HarbourFox HarbourBay BullsLatchfordRushoonParkers CoveCobaltWhitbourneSeal CoveConception Bay SouthChapel ArmRameaBelleoramClarke's BeachBrigusBay L'ArgentHermitage-SandyvilleCupidsIsle aux MortsMurdochville