Solar Calculator Canada

Solar Power Calculator for Hermitage-Sandyville, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Hermitage-Sandyville
  • GPS Coordinates: 47.546214, -55.924428
  • Elevation: 9 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Hermitage-Sandyville: 36o
  • Average yearly irradiance: 1239.72 kWh/m2
  • Average yearly power output: 106242 kWh
Sun Path Hermitage-Sandyville

Average yearly irradiance delivered by the Sun in Hermitage-Sandyville is 1239.72/kWh/m2 at the optimal panel slope of 36o. After taking all losses into account, you can expect about 106242 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 36o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.5 46.53
February 2.39 67.06
March 3.48 107.97
April 4.56 136.94
May 4.81 149.1
June 4.75 142.41
July 4.55 140.98
August 4.52 140
September 4.02 120.65
October 2.93 90.72
November 1.88 56.49
December 1.32 40.87
Total yearly 1239.72

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 128.79 3992.39
February 206.14 5772.05
March 299.06 9270.77
April 389.76 11692.8
May 410.76 12733.7
June 405.01 12150.2
July 388.31 12037.6
August 386.95 11995.3
September 345.69 10370.8
October 252.9 7840.04
November 163.07 4891.98
December 112.71 3494.14
Total yearly 106242

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Hermitage-Sandyville solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 99.63 3088.48
February 171.7 4807.71
March 272.21 8438.42
April 380.82 11424.7
May 425.89 13202.7
June 430.14 12904.3
July 408.39 12660.2
August 388.57 12045.5
September 320.5 9615
October 215.59 6683.32
November 126.37 3791.01
December 83.82 2598.28
Total yearly 101260

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 107.96 3346.65
February 181.9 5093.11
March 281.17 8716.36
April 386.17 11585.1
May 425.36 13186.3
June 426.87 12806
July 406.45 12599.8
August 391.16 12126
September 329.43 9882.77
October 226.82 7031.27
November 136.82 4104.58
December 91.95 2850.48
Total yearly 103328

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 115.41 3577.83
February 190.83 5343.21
March 288.53 8944.29
April 389.53 11685.8
May 423.16 13118
June 422.3 12669.1
July 402.8 12486.9
August 391.86 12147.8
September 336.47 10094.2
October 236.53 7332.49
November 146.19 4385.74
December 99.3 3078.16
Total yearly 104863

Hermitage-Sandyville Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 122 3781.85
February 198.49 5557.81
March 294.25 9121.82
April 390.9 11727
May 418.86 12984.6
June 415.57 12467.2
July 397.25 12314.8
August 390.67 12110.9
September 341.62 10248.7
October 244.73 7586.65
November 154.47 4634.01
December 105.84 3280.96
Total yearly 105816

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.96% angle of incidence loss and -1.88% temperature and irradiance loss. This totals to about -14.3%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: