Solar Calculator Canada

Solar Power Calculator for Ladysmith, British Columbia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Ladysmith
  • GPS Coordinates: 48.993333, -123.815556
  • Elevation: 46 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Ladysmith: 38o
  • Average yearly irradiance: 1380.69 kWh/m2
  • Average yearly power output: 112865 kWh
Sun Path Ladysmith

Average yearly irradiance delivered by the Sun in Ladysmith is 1380.69/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 112865 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.67 51.75
February 2.76 77.3
March 3.3 102.38
April 4.41 132.39
May 5.14 159.31
June 5.01 150.37
July 6.25 193.82
August 5.75 178.36
September 4.69 140.74
October 2.95 91.48
November 1.93 57.95
December 1.45 44.84
Total yearly 1380.69

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 143.74 4455.83
February 237.66 6654.56
March 281.79 8735.6
April 370.96 11128.9
May 418.67 12978.8
June 401.17 12035.1
July 487.93 15125.8
August 451.55 13998
September 376.93 11307.9
October 245.4 7607.41
November 165.31 4959.16
December 125.1 3878.16
Total yearly 112865

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Ladysmith solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 103.54 3209.59
February 186.71 5227.75
March 251.68 7801.93
April 363.01 10890.3
May 434.84 13480
June 430.35 12910.4
July 515.27 15973.3
August 449.44 13932.8
September 341.55 10246.4
October 203.1 6296.16
November 121.8 3653.9
December 86 2665.91
Total yearly 106288

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 114.09 3536.87
February 200.56 5615.81
March 260.89 8087.64
April 367.86 11035.7
May 434.91 13482.1
June 426.77 12803
July 513.32 15912.8
August 454.42 14086.9
September 353.27 10598
October 215.11 6668.34
November 133.39 4001.83
December 96.16 2980.99
Total yearly 108810

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 123.63 3832.68
February 212.9 5961.16
March 268.57 8325.78
April 370.84 11125.3
May 432.97 13422
June 421.72 12651.5
July 509.24 15786.4
August 456.96 14165.6
September 362.83 10884.9
October 225.62 6994.37
November 143.85 4315.46
December 105.39 3267.15
Total yearly 110732

Ladysmith Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 132.15 4096.63
February 223.69 6263.23
March 274.7 8515.55
April 371.98 11159.3
May 428.87 13295
June 414.98 12449.4
July 503.08 15595.5
August 457.14 14171.5
September 370.16 11104.8
October 234.63 7273.6
November 153.15 4594.35
December 113.68 3524.02
Total yearly 112043

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.98% angle of incidence loss and -6.39% temperature and irradiance loss. This totals to about -18.25%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: