Solar Calculator Canada

Solar Power Calculator for Boissevain, Manitoba, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Boissevain
  • GPS Coordinates: 49.230556, -100.055
  • Elevation: 516 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Boissevain: 43o
  • Average yearly irradiance: 1608.7 kWh/m2
  • Average yearly power output: 137176 kWh
Sun Path Boissevain

Average yearly irradiance delivered by the Sun in Boissevain is 1608.7/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 137176 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.38 73.66
February 3.32 93.04
March 3.95 122.52
April 5.61 168.28
May 5.55 172.01
June 5.79 173.77
July 6.38 197.75
August 6.06 188.01
September 5.17 155.15
October 3.95 122.31
November 2.62 78.47
December 2.06 63.72
Total yearly 1608.7

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 228.59 7086.32
February 315.45 8832.69
March 356.03 11037
April 482.34 14470.1
May 462.21 14328.6
June 468.18 14045.2
July 509.12 15782.8
August 487.07 15099
September 426.28 12788.5
October 341.37 10582.5
November 236.51 7095.35
December 194.45 6028.04
Total yearly 137176

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Boissevain solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 145.99 4525.6
February 228.18 6388.97
March 303.65 9413.18
April 462.22 13866.5
May 486.68 15087
June 512.79 15383.6
July 547.78 16981.1
August 484.37 15015.5
September 378.14 11344.3
October 265.1 8218.03
November 160.23 4806.79
December 118.56 3675.25
Total yearly 124706

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 164.68 5105.03
February 248.71 6963.95
March 317.91 9855.35
April 472.13 14163.9
May 487.53 15113.4
June 509.76 15292.8
July 546.84 16951.9
August 491.1 15224.1
September 392.61 11778.4
October 283.74 8795.96
November 177.7 5330.91
December 135.58 4203.03
Total yearly 128779

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.76 5634.71
February 267.16 7480.59
March 330.08 10232.4
April 479.33 14379.8
May 486.11 15069.4
June 504.39 15131.7
July 543.54 16849.6
August 495.06 15346.9
September 404.57 12137.2
October 300.29 9309.13
November 193.58 5807.37
December 151.21 4687.42
Total yearly 132066

Boissevain Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 197.2 6113.29
February 283.5 7937.96
March 340.11 10543.5
April 483.84 14515.2
May 482.41 14954.7
June 497.26 14917.7
July 537.17 16652.2
August 496.28 15384.6
September 413.98 12419.5
October 314.71 9756.04
November 207.83 6234.94
December 165.38 5126.83
Total yearly 134557

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -2.64% temperature and irradiance loss. This totals to about -14.73%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

RadissonMcAdamSouth RiverMintoNeguacNakuspPort AliceAshcroftWinnipegosisValemountVillage of Daajing GiidsMcBrideMassetFraser LakeBurns Lakenear TeslinMayoWindsorLondonSaint JohnMontrealDrummondvilleMonctonSault Ste. MarieBathurstMurdochville