Solar Calculator Canada

Solar Power Calculator for Emerson, Manitoba, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Emerson
  • GPS Coordinates: 49.006944, -97.214722
  • Elevation: 241 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Emerson: 42o
  • Average yearly irradiance: 1569.94 kWh/m2
  • Average yearly power output: 133647 kWh
Sun Path Emerson

Average yearly irradiance delivered by the Sun in Emerson is 1569.94/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 133647 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.37 73.38
February 3.3 92.49
March 3.9 120.76
April 5.54 166.21
May 5.37 166.61
June 5.72 171.48
July 6.43 199.23
August 5.88 182.17
September 4.99 149.82
October 3.6 111.68
November 2.44 73.15
December 2.03 62.98
Total yearly 1569.94

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 230.65 7150.03
February 314.63 8809.76
March 350.87 10877
April 475.15 14254.6
May 445.73 13817.5
June 460 13800
July 511.73 15863.7
August 469.97 14569.2
September 411.53 12345.8
October 309.92 9607.64
November 219.2 6576.09
December 192.78 5976.14
Total yearly 133647

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Emerson solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 148.27 4596.51
February 230.53 6454.95
March 300.05 9301.48
April 455.78 13673.2
May 468.74 14530.9
June 502.37 15071.1
July 547.05 16958.7
August 468.09 14510.7
September 367.14 11014.3
October 244.68 7585.03
November 151.5 4545
December 119.01 3689.46
Total yearly 121931

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 167.17 5182.26
February 250.63 7017.76
March 314.08 9736.46
April 465.49 13964.7
May 469.31 14548.7
June 499.28 14978.4
July 546.17 16931.2
August 474.31 14703.5
September 380.76 11422.7
October 260.97 8090.19
November 167.25 5017.53
December 135.77 4208.99
Total yearly 125802

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 184.44 5717.65
February 268.7 7523.58
March 326.04 10107.2
April 472.42 14172.5
May 467.8 14501.8
June 493.9 14816.9
July 542.68 16823
August 477.99 14817.8
September 391.96 11758.9
October 275.4 8537.49
November 181.58 5447.29
December 151.17 4686.37
Total yearly 128910

Emerson Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 200.04 6201.38
February 284.69 7971.33
March 335.89 10412.6
April 476.58 14297.5
May 464.32 14394
June 486.43 14593
July 536.98 16646.5
August 478.99 14848.6
September 400.72 12021.5
October 287.92 8925.47
November 194.43 5832.85
December 165.16 5119.82
Total yearly 131264

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.76% angle of incidence loss and -2.73% temperature and irradiance loss. This totals to about -14.87%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: