The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Morden
  • GPS Coordinates: 49.191944, -98.100556
  • Elevation: 303 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Morden: 42o
  • Average yearly irradiance: 1593.13 kWh/m2
  • Average yearly power output: 136370 kWh
Sun Path Morden

Average yearly irradiance delivered by the Sun in Morden is 1593.13/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 136370 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.49 77.09
February 3.4 95.09
March 4.04 125.25
April 5.59 167.8
May 5.33 165.38
June 5.69 170.57
July 6.44 199.64
August 5.93 183.98
September 5.03 151.03
October 3.77 116.72
November 2.53 75.82
December 2.09 64.76
Total yearly 1593.13

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 241.58 7489.11
February 323.96 9070.79
March 365.5 11330.4
April 482.78 14483.5
May 445.16 13800
June 459.87 13796.1
July 515.46 15979.2
August 477.16 14792.1
September 416.76 12502.8
October 326.14 10110.4
November 228.76 6862.89
December 198.48 6153
Total yearly 136370

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Morden solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 154.31 4783.72
February 236.63 6625.62
March 312.59 9690.4
April 462.55 13876.6
May 469 14539
June 504.13 15124
July 552.5 17127.6
August 474.76 14717.5
September 371.12 11133.7
October 255.07 7907.02
November 156.23 4686.76
December 121.83 3776.86
Total yearly 123989

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.09 5396.7
February 257.29 7204.02
March 327.1 10140.2
April 472.58 14177.3
May 469.6 14557.7
June 500.91 15027.2
July 551.63 17100.4
August 481.32 14920.9
September 385.01 11550.2
October 272.56 8449.29
November 172.89 5186.6
December 139.05 4310.64
Total yearly 128021

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 192.17 5957.41
February 275.86 7724.04
March 339.46 10523.4
April 479.84 14395.2
May 468.04 14509.4
June 495.38 14861.5
July 548.22 16994.7
August 485.22 15041.8
September 396.46 11893.7
October 288.08 8930.34
November 188.05 5641.39
December 154.87 4801.04
Total yearly 131274

Morden Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 208.53 6464.34
February 292.3 8184.49
March 349.64 10839
April 484.23 14527
May 464.69 14405.4
June 487.83 14635
July 542.43 16815.3
August 486.37 15077.4
September 405.43 12162.8
October 301.57 9348.63
November 201.66 6049.7
December 169.23 5246.27
Total yearly 133755

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.74% angle of incidence loss and -2.21% temperature and irradiance loss. This totals to about -14.4%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

RadissonMcAdamSouth RiverMintoNeguacNakuspPort AliceAshcroftWinnipegosisValemountVillage of Daajing GiidsMcBrideMassetFraser LakeBurns Lakenear TeslinMayoWindsorLondonSaint JohnMontrealDrummondvilleMonctonSault Ste. MarieBathurstMurdochville