Solar Calculator Canada

Solar Power Calculator for Clarenville, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Clarenville
  • GPS Coordinates: 48.1881389, -54.0557138
  • Elevation: 253 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Clarenville: 39o
  • Average yearly irradiance: 1275.35 kWh/m2
  • Average yearly power output: 108556 kWh
Sun Path Clarenville

Average yearly irradiance delivered by the Sun in Clarenville is 1275.35/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 108556 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.88 58.23
February 2.66 74.36
March 3.08 95.53
April 4.24 127.2
May 4.66 144.37
June 4.86 145.93
July 5.02 155.55
August 4.4 136.54
September 4.1 122.97
October 2.99 92.72
November 2.21 66.27
December 1.8 55.67
Total yearly 1275.35

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 172.48 5346.86
February 242.57 6791.86
March 274.86 8520.65
April 368.03 11041
May 393.29 12192
June 401.05 12031.6
July 405.78 12579.3
August 357.13 11071
September 339.74 10192.2
October 255.47 7919.57
November 194.63 5838.83
December 162.27 5030.44
Total yearly 108556

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Clarenville solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 120.36 3731.21
February 187.85 5259.86
March 245.3 7604.37
April 361.52 10845.7
May 413.38 12814.9
June 433.28 12998.4
July 432.18 13397.6
August 361.36 11202.3
September 311.71 9351.3
October 210.02 6510.75
November 140.28 4208.46
December 107.26 3325.01
Total yearly 101250

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 133.34 4133.65
February 202.09 5658.55
March 254.39 7885.95
April 366.7 11001.1
May 412.65 12792.3
June 429.91 12897.2
July 430.36 13341.1
August 364 11283.8
September 321.22 9636.61
October 222.37 6893.62
November 153.99 4619.69
December 120.77 3743.96
Total yearly 103888

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 145.17 4500.27
February 214.81 6014.61
March 261.94 8120.14
April 369.95 11098.5
May 410.18 12715.7
June 424.73 12742
July 426.83 13231.7
August 364.8 11308.8
September 328.83 9864.79
October 233.22 7229.67
November 166.42 4992.64
December 133.18 4128.5
Total yearly 105947

Clarenville Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 155.8 4829.88
February 225.97 6327.03
March 267.94 8306.19
April 371.11 11133.3
May 406.34 12596.5
June 418.32 12549.7
July 421.27 13059.2
August 363.81 11278
September 334.5 10034.9
October 242.51 7517.74
November 177.54 5326.1
December 144.42 4477
Total yearly 107436

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.02% angle of incidence loss and -2.48% temperature and irradiance loss. This totals to about -14.88%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville