Solar Calculator Canada

Solar Power Calculator for Manning, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Manning
  • GPS Coordinates: 56.9222222, -117.6283333
  • Elevation: 462 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Manning: 44o
  • Average yearly irradiance: 1306.39 kWh/m2
  • Average yearly power output: 108985 kWh
Sun Path Manning

Average yearly irradiance delivered by the Sun in Manning is 1306.39/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 108985 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 0.94 29.24
February 1.92 53.82
March 3.22 99.7
April 5.08 152.52
May 5.99 185.54
June 5.86 175.89
July 5.79 179.44
August 5.2 161.13
September 4.22 126.58
October 2.81 87.18
November 1.29 38.64
December 0.54 16.72
Total yearly 1306.39

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 85.62 2654.11
February 173.77 4865.56
March 284.23 8811.26
April 433.87 13016.2
May 492.85 15278.4
June 471.38 14141.5
July 460.8 14284.7
August 417.91 12955.3
September 349.06 10471.7
October 241.98 7501.38
November 115.63 3468.79
December 49.56 1536.5
Total yearly 108985

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Manning solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 50.07 1552.18
February 118.78 3325.75
March 230.69 7151.44
April 398.62 11958.5
May 495.43 15358.4
June 496.55 14896.5
July 474.96 14723.7
August 401.41 12443.8
September 295.07 8852.05
October 174.61 5412.86
November 68.62 2058.75
December 25.04 776.09
Total yearly 98510.1

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 57.9 1794.9
February 131.5 3681.9
March 244.29 7572.92
April 410.25 12307.6
May 500.28 15508.7
June 496.41 14892.3
July 477.07 14789.2
August 409.37 12690.6
September 309.27 9278.12
October 190.19 5895.8
November 78.98 2369.37
December 30.32 940.05
Total yearly 101721

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 65.1 2018.25
February 143 4004.12
March 256.15 7940.79
April 419.38 12581.4
May 502.65 15582.1
June 494.73 14842
July 477.7 14808.7
August 414.9 12861.8
September 321.44 9643.21
October 204.25 6331.72
November 88.5 2654.91
December 35.24 1092.51
Total yearly 104361

Manning Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 71.66 2221.42
February 153.28 4291.96
March 266.28 8254.59
April 426.07 12782
May 502.77 15585.8
June 491.14 14734.1
July 475.86 14751.5
August 418.13 12962.1
September 331.55 9946.49
October 216.75 6719.26
November 97.15 2914.39
December 39.76 1232.56
Total yearly 106396

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.8% angle of incidence loss and -4.64% temperature and irradiance loss. This totals to about -16.58%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.