Solar Calculator Canada

Solar Power Calculator for Embree, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Embree
  • GPS Coordinates: 49.3012472, -55.0437028
  • Elevation: 25 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Embree: 37o
  • Average yearly irradiance: 1231.84 kWh/m2
  • Average yearly power output: 105466 kWh
Sun Path Embree

Average yearly irradiance delivered by the Sun in Embree is 1231.84/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 105466 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.51 46.83
February 2.12 59.23
March 2.95 91.33
April 4.24 127.25
May 4.76 147.57
June 4.95 148.43
July 5.34 165.47
August 4.71 146.1
September 4 120.03
October 2.72 84.37
November 1.87 56.03
December 1.26 39.21
Total yearly 1231.84

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 129.8 4023.83
February 181.11 5070.96
March 250.9 7777.93
April 361.56 10846.7
May 406.38 12597.9
June 422.09 12662.8
July 456.91 14164.2
August 404.08 12526.4
September 343.77 10313
October 234.82 7279.28
November 161.8 4854.07
December 108.03 3348.96
Total yearly 105466

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Embree solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 95.5 2960.52
February 147.5 4130.11
March 227.11 7040.51
April 353.18 10595.5
May 419.24 12996.4
June 447.22 13416.7
July 477.23 14794.1
August 402.89 12489.5
September 315.98 9479.33
October 197.11 6110.55
November 121.66 3649.74
December 76.64 2375.8
Total yearly 100039

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.87 3250.88
February 157.1 4398.81
March 234.86 7280.76
April 358.15 10744.5
May 419.25 12996.8
June 444.32 13329.6
July 476.1 14759.2
August 406.5 12601.6
September 325.56 9766.83
October 208.15 6452.76
November 132.73 3981.95
December 85.12 2638.84
Total yearly 102202

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 113.36 3514.12
February 165.59 4636.39
March 241.26 7479.15
April 361.3 10839
May 417.52 12943
June 439.59 13187.7
July 473.12 14666.9
August 408.08 12650.4
September 333.26 9997.66
October 217.8 6751.81
November 142.71 4281.44
December 92.86 2878.8
Total yearly 103826

Embree Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 120.95 3749.46
February 172.94 4842.41
March 246.3 7635.36
April 362.72 10881.6
May 414.09 12836.9
June 433.58 13007.5
July 467.74 14499.8
August 407.68 12638.2
September 339.05 10171.4
October 226.03 7007.05
November 151.59 4547.58
December 99.83 3094.77
Total yearly 104912

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.98% angle of incidence loss and -1.94% temperature and irradiance loss. This totals to about -14.38%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Flower's CoveGovanIrricanaSpringsideImperialRaymoreCrossfieldNokomisSt. Lunaire-GriquetL'Anse au LoupRaleighCarstairsCook's HarbourZealandiaPinwareHanleyFoam LakeDidsburyThree HillsRed BayOldsSundreDundurnTrochuNorquayMurdochville