Solar Calculator Canada

Solar Power Calculator for Raymore, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Raymore
  • GPS Coordinates: 51.4088111, -104.5265667
  • Elevation: 621 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Raymore: 42o
  • Average yearly irradiance: 1520.85 kWh/m2
  • Average yearly power output: 129741 kWh
Sun Path Raymore

Average yearly irradiance delivered by the Sun in Raymore is 1520.85/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 129741 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.83 56.74
February 2.7 75.61
March 3.73 115.49
April 5.35 160.63
May 5.89 182.46
June 5.77 173.12
July 6.38 197.68
August 5.85 181.29
September 5.02 150.5
October 3.77 116.78
November 2.18 65.32
December 1.46 45.24
Total yearly 1520.85

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 175.92 5453.65
February 256.66 7186.44
March 336.4 10428.4
April 461.99 13859.6
May 492.49 15267.3
June 469.68 14090.5
July 512.78 15896.2
August 472.25 14639.9
September 417.8 12533.9
October 327.54 10153.7
November 198.09 5942.83
December 138.35 4288.91
Total yearly 129741

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Raymore solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 109.65 3399.09
February 184.65 5170.12
March 281.34 8721.4
April 439.77 13193.2
May 513.08 15905.5
June 509.26 15277.8
July 543.11 16836.3
August 464.93 14412.8
September 365.23 10956.9
October 248.14 7692.3
November 131.57 3947.01
December 83.06 2574.87
Total yearly 118087

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 124.57 3861.8
February 201.55 5643.46
March 295.87 9171.9
April 449.68 13490.5
May 515.55 15982
June 507.32 15219.6
July 543.84 16859.1
August 472.06 14634
September 380.47 11414.1
October 267.23 8284.23
November 146.75 4402.53
December 95.39 2957.09
Total yearly 121920

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 138.21 4284.48
February 216.77 6069.67
March 308.36 9559.27
April 457.01 13710.3
May 515.11 15968.4
June 503.62 15108.6
July 541.67 16791.6
August 476.51 14771.8
September 393.24 11797.3
October 284.3 8813.16
November 160.59 4817.71
December 106.72 3308.47
Total yearly 125001

Raymore Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 150.53 4666.42
February 230.29 6447.99
March 318.8 9882.8
April 461.73 13852
May 511.89 15868.5
June 496.65 14899.6
July 536.27 16624.4
August 478.29 14826.8
September 403.5 12105.1
October 299.27 9277.51
November 173.05 5191.4
December 117.03 3627.89
Total yearly 127270

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.75% angle of incidence loss and -2.54% temperature and irradiance loss. This totals to about -14.69%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville