The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Englee
  • GPS Coordinates: 50.7657028, -56.0709528
  • Elevation: 128 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Englee: 38o
  • Average yearly irradiance: 1202.72 kWh/m2
  • Average yearly power output: 102913 kWh
Sun Path Englee

Average yearly irradiance delivered by the Sun in Englee is 1202.72/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 102913 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.53 47.42
February 2.45 68.61
March 3.15 97.52
April 4.16 124.94
May 4.53 140.49
June 4.93 147.9
July 5.02 155.66
August 4.39 136.21
September 3.61 108.21
October 2.58 79.88
November 1.76 52.78
December 1.39 43.1
Total yearly 1202.72

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.25 4068.62
February 210.05 5881.36
March 268.28 8316.56
April 353.95 10618.6
May 386.28 11974.6
June 420.5 12614.9
July 429.67 13319.7
August 376.12 11659.7
September 309.85 9295.4
October 222.25 6889.89
November 152.03 4560.97
December 119.77 3712.85
Total yearly 102913

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Englee solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 93.8 2907.7
February 164.57 4608.03
March 238.74 7400.91
April 344.11 10323.4
May 401.23 12438.2
June 446.61 13398.3
July 450.53 13966.5
August 375.17 11630.2
September 283.72 8511.61
October 183.75 5696.1
November 110.75 3322.6
December 80.82 2505.34
Total yearly 96708.8

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 103.48 3208.02
February 176.76 4949.27
March 247.74 7679.85
April 349.61 10488.3
May 401.22 12437.8
June 444.12 13323.5
July 449.63 13938.5
August 378.82 11743.3
September 292.52 8775.53
October 194.39 6026.13
November 121.39 3641.69
December 90.81 2815.23
Total yearly 99027.1

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 112.21 3478.44
February 187.55 5251.51
March 255.24 7912.33
April 353.27 10598.1
May 399.56 12386.4
June 439.78 13193.4
July 447.03 13857.9
August 380.54 11796.6
September 299.61 8988.36
October 203.7 6314.7
November 130.97 3929.01
December 99.89 3096.49
Total yearly 100803

Englee Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.97 3718.99
February 196.96 5514.81
March 261.23 8098.28
April 355.08 10652.5
May 396.22 12282.7
June 434.15 13024.6
July 442.09 13704.7
August 380.35 11791
September 304.99 9149.7
October 211.66 6561.41
November 139.48 4184.31
December 108.03 3348.99
Total yearly 102032

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.93% angle of incidence loss and -2.06% temperature and irradiance loss. This totals to about -14.43%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville