Solar Calculator Canada

Solar Power Calculator for Gambo, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Gambo
  • GPS Coordinates: 48.7970805, -54.2125111
  • Elevation: 54 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Gambo: 39o
  • Average yearly irradiance: 1250.36 kWh/m2
  • Average yearly power output: 105788 kWh
Sun Path Gambo

Average yearly irradiance delivered by the Sun in Gambo is 1250.36/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 105788 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.74 53.95
February 2.38 66.74
March 2.99 92.71
April 4.29 128.65
May 4.62 143.14
June 4.86 145.82
July 5.08 157.53
August 4.4 136.55
September 4.04 121.24
October 2.88 89.32
November 2.16 64.85
December 1.61 49.86
Total yearly 1250.36

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 158.95 4927.37
February 216.42 6059.62
March 265.88 8242.33
April 371.02 11130.6
May 387.87 12024
June 397.86 11935.8
July 407.93 12645.9
August 355.11 11008.4
September 334.16 10024.8
October 245.46 7609.37
November 190.07 5701.97
December 144.44 4477.62
Total yearly 105788

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Gambo solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 111.51 3456.89
February 169.51 4746.21
March 237.81 7372.25
April 363.38 10901.5
May 405.76 12578.7
June 427.73 12831.9
July 431.64 13380.8
August 358.08 11100.6
September 305.68 9170.45
October 202.04 6263.27
November 136.78 4103.38
December 96.66 2996.52
Total yearly 98902.4

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 123.39 3825.18
February 181.84 5091.4
March 246.5 7641.53
April 368.76 11062.9
May 405.32 12564.9
June 424.64 12739.1
July 430.24 13337.6
August 360.85 11186.3
September 315.24 9457.17
October 213.91 6631.3
November 150.31 4509.34
December 108.49 3363.26
Total yearly 101410

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 134.22 4160.96
February 192.83 5399.1
March 253.72 7865.37
April 372.22 11166.7
May 403.16 12498
June 419.76 12592.7
July 427.12 13240.6
August 361.81 11216.2
September 322.93 9687.92
October 224.34 6954.65
November 162.59 4877.82
December 119.35 3699.79
Total yearly 103360

Gambo Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 143.97 4463.03
February 202.44 5668.43
March 259.45 8043.09
April 373.62 11208.7
May 399.61 12387.8
June 413.66 12409.9
July 421.97 13081
August 361.01 11191.2
September 328.73 9861.79
October 233.29 7232.14
November 173.59 5207.61
December 129.18 4004.67
Total yearly 104759

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.03% angle of incidence loss and -3.06% temperature and irradiance loss. This totals to about -15.39%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

RadissonMcAdamSouth RiverMintoNeguacNakuspPort AliceAshcroftWinnipegosisValemountVillage of Daajing GiidsMcBrideMassetFraser LakeBurns Lakenear TeslinMayoWindsorLondonSaint JohnMontrealDrummondvilleMonctonSault Ste. MarieBathurstMurdochville