Solar Calculator Canada

Solar Power Calculator for Lewisporte, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Lewisporte
  • GPS Coordinates: 49.244728, -55.058517
  • Elevation: 3 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Lewisporte: 39o
  • Average yearly irradiance: 1264.78 kWh/m2
  • Average yearly power output: 107621 kWh
Sun Path Lewisporte

Average yearly irradiance delivered by the Sun in Lewisporte is 1264.78/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 107621 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.78 55.05
February 2.51 70.42
March 3.13 96.98
April 4.35 130.65
May 4.64 143.86
June 4.86 145.81
July 5.27 163.38
August 4.59 142.16
September 3.98 119.47
October 2.84 88.19
November 2.03 60.78
December 1.55 48.05
Total yearly 1264.78

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 163.34 5063.43
February 230.8 6462.31
March 280.58 8698.13
April 379.84 11395.3
May 392.56 12169.4
June 399.3 11979
July 424.85 13170.5
August 371.19 11506.9
September 330.95 9928.51
October 243.57 7550.75
November 178.78 5363.33
December 139.8 4333.67
Total yearly 107621

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Lewisporte solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 112.72 3494.39
February 177.92 4981.83
March 249.09 7721.77
April 370.65 11119.5
May 410.31 12719.6
June 429.13 12873.9
July 449.19 13924.8
August 372.54 11548.8
September 302.07 9062.2
October 199.12 6172.72
November 128.45 3853.65
December 92.27 2860.3
Total yearly 100333

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 125.2 3881.16
February 191.55 5363.45
March 258.59 8016.27
April 376.47 11294.1
May 410.19 12715.9
June 426.3 12789.1
July 448.17 13893.3
August 375.96 11654.8
September 311.66 9349.68
October 211.12 6544.78
November 141.07 4231.98
December 103.84 3218.93
Total yearly 102953

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 136.6 4234.54
February 203.74 5704.82
March 266.54 8262.65
April 380.27 11408.1
May 408.3 12657.4
June 421.65 12649.5
July 445.33 13805.2
August 377.44 11700.6
September 319.39 9581.67
October 221.69 6872.46
November 152.52 4575.69
December 114.48 3548.79
Total yearly 105001

Lewisporte Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 146.88 4553.17
February 214.46 6004.91
March 272.91 8460.08
April 382.13 11463.9
May 404.72 12546.4
June 415.7 12471
July 440.12 13643.9
August 377.03 11687.9
September 325.24 9757.22
October 230.79 7154.53
November 162.78 4883.54
December 124.14 3848.27
Total yearly 106475

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.97% angle of incidence loss and -2.56% temperature and irradiance loss. This totals to about -14.91%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

RadissonMcAdamSouth RiverMintoNeguacNakuspPort AliceAshcroftWinnipegosisValemountVillage of Daajing GiidsMcBrideMassetFraser LakeBurns Lakenear TeslinMayoWindsorLondonSaint JohnMontrealDrummondvilleMonctonSault Ste. MarieBathurstMurdochville