Solar Calculator Canada

Solar Power Calculator for Musgrave Harbour, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Musgrave Harbour
  • GPS Coordinates: 49.4167028, -53.9644222
  • Elevation: 38 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Musgrave Harbour: 37o
  • Average yearly irradiance: 1221.03 kWh/m2
  • Average yearly power output: 103747 kWh
Sun Path Musgrave Harbour

Average yearly irradiance delivered by the Sun in Musgrave Harbour is 1221.03/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 103747 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.24 38.33
February 1.86 52.13
March 2.82 87.48
April 4.38 131.32
May 4.88 151.3
June 5.15 154.65
July 5.39 167.19
August 4.81 149.16
September 4.02 120.61
October 2.61 80.96
November 1.84 55.06
December 1.06 32.86
Total yearly 1221.03

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 110.27 3418.45
February 167.79 4698.22
March 252.61 7830.85
April 384.52 11535.5
May 416.84 12921.9
June 428.27 12848.2
July 438.43 13591.5
August 393.11 12186.4
September 336.3 10088.9
October 223.58 6931.1
November 161.05 4831.48
December 92.39 2864.15
Total yearly 103747

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Musgrave Harbour solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 82.28 2550.64
February 136.7 3827.68
March 227.44 7050.61
April 373.23 11197
May 429.06 13300.9
June 452.53 13576
July 456.49 14151.2
August 390.21 12096.5
September 306.52 9195.62
October 187.11 5800.47
November 119.41 3582.44
December 66.25 2053.73
Total yearly 98382.8

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 89.96 2788.75
February 145.62 4077.46
March 235.61 7303.85
April 379.25 11377.5
May 429.28 13307.7
June 449.92 13497.7
July 455.62 14124.3
August 394.26 12221.9
September 316.61 9498.26
October 197.82 6132.35
November 130.87 3926.17
December 73.31 2272.65
Total yearly 100529

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 96.94 3005.08
February 153.54 4299.08
March 242.39 7514.2
April 383.31 11499.3
May 427.61 13255.9
June 445.33 13359.8
July 452.84 14037.9
August 396.23 12283.1
September 324.8 9743.99
October 207.22 6423.71
November 141.28 4238.32
December 79.79 2473.38
Total yearly 102134

Musgrave Harbour Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 103.18 3198.69
February 160.42 4491.75
March 247.77 7680.96
April 385.2 11556.1
May 424.43 13157.3
June 439.3 13179.1
July 447.97 13887.2
August 396.17 12281.4
September 331.06 9931.78
October 215.27 6673.41
November 150.59 4517.7
December 85.64 2654.77
Total yearly 103210

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3% angle of incidence loss and -2.67% temperature and irradiance loss. This totals to about -15.03%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

RadissonMcAdamSouth RiverMintoNeguacNakuspPort AliceAshcroftWinnipegosisValemountVillage of Daajing GiidsMcBrideMassetFraser LakeBurns Lakenear TeslinMayoWindsorLondonSaint JohnMontrealDrummondvilleMonctonSault Ste. MarieBathurstMurdochville