Solar Calculator Canada

Solar Power Calculator for Placentia, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Placentia
  • GPS Coordinates: 47.2705222, -53.9050916
  • Elevation: 33 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Placentia: 37o
  • Average yearly irradiance: 1248.33 kWh/m2
  • Average yearly power output: 107224 kWh
Sun Path Placentia

Average yearly irradiance delivered by the Sun in Placentia is 1248.33/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 107224 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.4 43.51
February 2.33 65.21
March 3.38 104.67
April 4.55 136.5
May 4.79 148.46
June 4.79 143.58
July 4.79 148.34
August 4.57 141.63
September 4.13 123.85
October 2.89 89.47
November 1.97 59.08
December 1.42 44.04
Total yearly 1248.33

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 125.85 3901.33
February 211.63 5925.51
March 304.7 9445.81
April 401.51 12045.3
May 412.11 12775.5
June 402.48 12074.3
July 394.61 12233
August 376.09 11658.8
September 346.13 10384
October 248.15 7692.73
November 172.73 5182.02
December 125.99 3905.59
Total yearly 107224

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Placentia solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 95.87 2972.12
February 174.38 4882.54
March 274.98 8524.35
April 392.06 11761.7
May 428.21 13274.4
June 428.55 12856.5
July 415.37 12876.5
August 376.72 11678.4
September 319.78 9593.52
October 209.95 6508.47
November 131.81 3954.32
December 90.82 2815.29
Total yearly 101698

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.16 3229
February 185.1 5182.7
March 284.57 8821.65
April 397.78 11933.3
May 427.68 13258
June 425.29 12758.6
July 413.4 12815.4
August 379.77 11772.8
September 329.08 9872.42
October 221.14 6855.3
November 143.11 4293.25
December 100.35 3110.82
Total yearly 103903

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 111.67 3461.73
February 194.58 5448.33
March 292.51 9067.85
April 401.33 12039.9
May 425.25 13182.8
June 420.26 12607.8
July 409.86 12705.6
August 380.83 11805.7
September 336.45 10093.6
October 230.9 7157.9
November 153.32 4599.48
December 109.06 3380.92
Total yearly 105552

Placentia Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 118.36 3669.29
February 202.8 5678.35
March 298.77 9261.79
April 402.73 12082
May 421.18 13056.5
June 413.94 12418.2
July 404.36 12535.1
August 379.94 11778.3
September 341.87 10256.1
October 239.19 7415.01
November 162.39 4871.84
December 116.92 3624.39
Total yearly 106647

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.02% angle of incidence loss and -1.59% temperature and irradiance loss. This totals to about -14.11%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

The PasSt. PaulBarrheadWhitecourtWestlockBonnyvilleFox CreekSwan HillsAthabascaLac La BicheSmithersSnow LakeValleyviewSlave LakeHigh PrairieSpirit RiverFairviewGrimshawPeace RiverGillamLeaf RapidsManningRainbow LakeT�te-�-la-BaleineLa Tabati�reMurdochville