Solar Calculator Canada

Solar Power Calculator for St. Lunaire-Griquet, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: St. Lunaire-Griquet
  • GPS Coordinates: 51.5205361, -55.4808889
  • Elevation: 62 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for St. Lunaire-Griquet: 39o
  • Average yearly irradiance: 1192.4 kWh/m2
  • Average yearly power output: 101752 kWh
Sun Path St. Lunaire-Griquet

Average yearly irradiance delivered by the Sun in St. Lunaire-Griquet is 1192.4/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 101752 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.31 40.65
February 2.2 61.5
March 2.77 85.84
April 3.91 117.33
May 4.68 145.16
June 5.11 153.25
July 5.06 156.76
August 4.61 142.82
September 3.71 111.19
October 2.53 78.38
November 1.9 57.11
December 1.37 42.43
Total yearly 1192.4

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 111.45 3454.84
February 186.32 5216.95
March 232.34 7202.46
April 330.58 9917.37
May 399.54 12385.8
June 435.67 13070
July 431.98 13391.5
August 394.64 12233.7
September 317.91 9537.37
October 217.42 6740.01
November 164.93 4947.76
December 117.86 3653.79
Total yearly 101752

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

St. Lunaire-Griquet solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 77 2387.08
February 141.97 3975.06
March 204.35 6334.96
April 321.12 9633.57
May 413.93 12831.9
June 462.39 13871.8
July 452.23 14019.1
August 391.81 12146.1
September 288.46 8653.79
October 177.46 5501.27
November 115.68 3470.4
December 76.28 2364.73
Total yearly 95189.7

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 85.71 2657.01
February 153.56 4299.55
March 212.69 6593.46
April 326.33 9790.01
May 414.31 12843.5
June 460.49 13814.7
July 451.86 14007.5
August 396.26 12284
September 297.94 8938.13
October 188.26 5836.14
November 128.12 3843.56
December 86.63 2685.38
Total yearly 97592.9

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 93.59 2901.43
February 163.88 4588.68
March 219.69 6810.43
April 329.8 9894.01
May 412.93 12800.9
June 456.62 13698.7
July 449.73 13941.7
August 398.65 12358
September 305.67 9170.02
October 197.76 6130.5
November 139.4 4181.89
December 96.07 2978.14
Total yearly 99454.4

St. Lunaire-Griquet Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 100.65 3120.02
February 172.94 4842.29
March 225.35 6985.94
April 331.67 9950.01
May 409.96 12708.6
June 451.39 13541.6
July 445.48 13809.9
August 399.05 12370.5
September 311.63 9348.76
October 205.93 6383.78
November 149.49 4484.72
December 104.59 3242.41
Total yearly 100789

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.93% angle of incidence loss and -2.32% temperature and irradiance loss. This totals to about -14.67%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Saint-Donat-de-MontcalmSaint-OdilonSaint-Barnab�-NordSaint-Camille-de-BellechasseSaint-�douardProulxvilleTee LakeSaint-Cyrille-de-L'IsletL'Islet-sur-MerFabreHavre-AubertPetite-Rivi�reLes �troitsSaint-Bernard-sur-MerSullyEstcourtGuiguesSaint-Fid�leSaint-AntoninSquatecPointe-�-la-GardeLac-HumquiLes Hauteurs-de-RimouskiRivi�re-PortneufL'AscensionMurdochville