Solar Calculator Canada

Solar Power Calculator for Saint-Camille-de-Bellechasse, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Saint-Camille-de-Bellechasse
  • GPS Coordinates: 46.4938889, -70.2130556
  • Elevation: 409 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Saint-Camille-de-Bellechasse: 40o
  • Average yearly irradiance: 1486.94 kWh/m2
  • Average yearly power output: 126788 kWh
Sun Path Saint-Camille-de-Bellechasse

Average yearly irradiance delivered by the Sun in Saint-Camille-de-Bellechasse is 1486.94/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 126788 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 3.05 94.64
February 3.62 101.37
March 4.38 135.71
April 4.81 144.18
May 4.95 153.51
June 5.13 153.79
July 5.47 169.6
August 5.12 158.79
September 4.49 134.6
October 3.24 100.58
November 2.49 74.58
December 2.12 65.58
Total yearly 1486.94

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 291.32 9031.02
February 339.68 9511.04
March 394.46 12228.2
April 413.49 12404.8
May 409.46 12693.3
June 412.76 12382.9
July 436.23 13523
August 411.15 12745.6
September 366.96 11008.9
October 276.53 8572.3
November 220.1 6602.96
December 196.25 6083.72
Total yearly 126788

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Saint-Camille-de-Bellechasse solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 199.72 6191.28
February 264.84 7415.39
March 348.56 10805.2
April 406.99 12209.8
May 433.78 13447.3
June 451.22 13536.6
July 469.28 14547.7
August 417.31 12936.8
September 338.35 10150.5
October 229.21 7105.42
November 161.07 4832.09
December 131.54 4077.63
Total yearly 117256

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 222.03 6882.84
February 283.94 7950.4
March 362.27 11230.3
April 412.79 12383.7
May 433.02 13423.7
June 447.37 13421
July 467.15 14481.6
August 420.39 13032.1
September 348.32 10449.7
October 241.95 7500.4
November 175.71 5271.25
December 147.15 4561.79
Total yearly 120589

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 242.31 7511.75
February 300.94 8426.4
March 373.75 11586.2
April 416.5 12495
May 430.39 13342
June 442.04 13261.2
July 462.83 14347.7
August 421.33 13061.3
September 356.21 10686.4
October 253.07 7845.12
November 188.91 5667.26
December 161.41 5003.57
Total yearly 123234

Saint-Camille-de-Bellechasse Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 260.53 8076.32
February 315.79 8842.17
March 382.95 11871.5
April 417.87 12536.1
May 425.7 13196.8
June 434.36 13030.8
July 456.11 14139.3
August 420.13 13024.1
September 362 10860
October 262.53 8138.48
November 200.64 6019.11
December 174.24 5401.59
Total yearly 125136

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.89% angle of incidence loss and -2.44% temperature and irradiance loss. This totals to about -14.73%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Roche PerceeMontroseCartwrightWaskadaFruitvaleTorquayLake AlmaCrystal CityMintonCarievaleGainsboroughSalmoFrontierKeremeosClimaxFrobisherGlen EwenVal MarieTribuneWarnerHill SpringConsulHarrison Hot SpringsMacounGlenwoodMurdochville