Solar Calculator Canada

Solar Power Calculator for Westport, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Westport
  • GPS Coordinates: 49.7877889, -56.617525
  • Elevation: 106 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Westport: 38o
  • Average yearly irradiance: 1227.03 kWh/m2
  • Average yearly power output: 104391 kWh
Sun Path Westport

Average yearly irradiance delivered by the Sun in Westport is 1227.03/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 104391 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.51 46.69
February 2.5 70.13
March 3.46 107.4
April 4.25 127.64
May 4.65 144.18
June 4.92 147.55
July 5.17 160.26
August 4.66 144.47
September 3.8 114.05
October 2.66 82.44
November 1.6 47.96
December 1.11 34.27
Total yearly 1227.03

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 138.06 4279.75
February 231.35 6477.83
March 313.87 9729.91
April 372.41 11172.2
May 392.58 12169.9
June 403.56 12106.9
July 417.34 12937.5
August 377.89 11714.7
September 317.14 9514.06
October 227.58 7054.83
November 139.83 4194.9
December 98.01 3038.24
Total yearly 104391

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Westport solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 100.63 3119.54
February 181.92 5093.89
March 275.24 8532.36
April 361.56 10846.7
May 406.93 12615
June 430.81 12924.3
July 438.86 13604.5
August 376.8 11680.8
September 289.4 8682.15
October 188.46 5842.36
November 105.35 3160.44
December 69.58 2157
Total yearly 98259

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 110.1 3413.15
February 195.04 5461.14
March 286.87 8892.99
April 367.56 11026.8
May 407.29 12626.1
June 428.39 12851.6
July 438.1 13581
August 380.67 11800.7
September 298.63 8958.97
October 199.17 6174.14
November 114.19 3425.77
December 76.65 2376.06
Total yearly 100588

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 118.66 3678.36
February 206.71 5787.87
March 296.72 9198.22
April 371.61 11148.3
May 405.97 12585.2
June 424.62 12738.6
July 435.45 13499
August 382.56 11859.5
September 306.1 9182.95
October 208.52 6464.27
November 122.14 3664.14
December 83.06 2574.78
Total yearly 102381

Westport Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 126.28 3914.68
February 216.91 6073.48
March 304.75 9447.19
April 373.7 11211
May 402.55 12479
June 418.53 12556
July 430.49 13345.2
August 382.49 11857.2
September 311.78 9353.38
October 216.52 6712.03
November 129.17 3875.06
December 88.79 2752.62
Total yearly 103577

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.91% angle of incidence loss and -2.64% temperature and irradiance loss. This totals to about -14.92%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: