Solar Calculator Canada

Solar Power Calculator for Villemontel, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Villemontel
  • GPS Coordinates: 48.6319444, -78.3625
  • Elevation: 318 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Villemontel: 41o
  • Average yearly irradiance: 1438 kWh/m2
  • Average yearly power output: 122721 kWh
Sun Path Villemontel

Average yearly irradiance delivered by the Sun in Villemontel is 1438/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 122721 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.57 79.64
February 3.6 100.94
March 4.64 143.82
April 4.76 142.65
May 5.34 165.66
June 5.5 165.09
July 5.31 164.57
August 4.98 154.4
September 4.17 125.06
October 2.84 87.98
November 1.89 56.83
December 1.66 51.35
Total yearly 1438

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 248.69 7709.24
February 343.07 9605.93
March 421.84 13077.1
April 409.97 12299.2
May 441.11 13674.5
June 442.05 13261.5
July 422.98 13112.4
August 400.38 12411.9
September 342.05 10261.4
October 241.19 7476.79
November 167.2 5016.01
December 155.33 4815.17
Total yearly 122721

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Villemontel solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 168.3 5217.36
February 261.6 7324.82
March 364.63 11303.7
April 399.89 11996.7
May 462.78 14346.3
June 479.07 14372
July 452.41 14024.7
August 402.57 12479.7
September 311.99 9359.73
October 199.34 6179.67
November 121.86 3655.86
December 104.01 3224.35
Total yearly 113485

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.58 5814.95
February 281.97 7895.05
March 380.87 11806.8
April 406.38 12191.5
May 463.46 14367.3
June 476.15 14284.6
July 450.83 13975.7
August 406.55 12603.1
September 321.87 9655.95
October 210.44 6523.59
November 132.92 3987.69
December 116.29 3605.07
Total yearly 116711

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 205.12 6358.6
February 300.17 8404.76
March 394.66 12234.4
April 410.71 12321.4
May 461.71 14312.9
June 471.68 14150.5
July 447.55 13874.2
August 408.39 12660
September 329.83 9894.8
October 220.13 6824.11
November 142.92 4287.74
December 127.47 3951.51
Total yearly 119275

Villemontel Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 220.88 6847.17
February 316.17 8852.86
March 405.97 12585.1
April 412.87 12386
May 457.59 14185.4
June 464.6 13937.9
July 442.04 13703.2
August 408.16 12653
September 335.86 10075.7
October 228.4 7080.27
November 151.83 4554.94
December 137.52 4263.02
Total yearly 121125

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.84% angle of incidence loss and -2.4% temperature and irradiance loss. This totals to about -14.66%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

ValparaisoBeattyRidgedaleWasecaMinburnWeirdaleLavoySpring LakeEntwistlePort ColborneThoroldCounty of BrantLambton ShoresBurlingtonCambridgeWaterlooBramptonVaughanPrince EdwardKawartha LakesHuntingdonSuttonBedfordDunhamCowansvilleMurdochville