Solar Calculator Canada

Solar Power Calculator for Woody Point, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Woody Point
  • GPS Coordinates: 49.49675, -57.9260389
  • Elevation: 78 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Woody Point: 33o
  • Average yearly irradiance: 1114.42 kWh/m2
  • Average yearly power output: 94048.5 kWh
Sun Path Woody Point

Average yearly irradiance delivered by the Sun in Woody Point is 1114.42/kWh/m2 at the optimal panel slope of 33o. After taking all losses into account, you can expect about 94048.5 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 33o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 0.64 19.84
February 1.31 36.77
March 2.38 73.84
April 4.07 122.19
May 5.07 157.12
June 5.3 158.98
July 5.18 160.63
August 4.66 144.45
September 3.52 105.53
October 2.41 74.64
November 1.33 39.93
December 0.66 20.48
Total yearly 1114.42

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 53.47 1657.61
February 115.1 3222.93
March 211.16 6545.85
April 356.74 10702.2
May 432.61 13411
June 439.51 13185.4
July 422.72 13104.4
August 381.2 11817.2
September 294.88 8846.28
October 206.26 6394.09
November 114.93 3447.96
December 55.28 1713.65
Total yearly 94048.5

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Woody Point solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 43.86 1359.63
February 98.86 2768.16
March 193.72 6005.23
April 346.9 10407.1
May 439.35 13619.9
June 456.31 13689.3
July 434.12 13457.6
August 375.81 11650.1
September 273.24 8197.31
October 177.27 5495.32
November 89.84 2695.06
December 42.9 1329.84
Total yearly 90674.6

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 46.99 1456.56
February 104.27 2919.49
March 199.99 6199.57
April 352.15 10564.5
May 440.34 13650.7
June 454.05 13621.5
July 433.75 13446.3
August 379.84 11775.1
September 281.43 8442.9
October 186.9 5794.05
November 97.84 2935.09
December 46.82 1451.36
Total yearly 92257.1

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 49.77 1542.86
February 108.98 3051.56
March 205.1 6358.02
April 355.51 10665.3
May 439.17 13614.3
June 450.26 13507.8
July 431.11 13364.4
August 381.87 11838
September 287.98 8639.5
October 195.31 6054.6
November 105.06 3151.91
December 50.35 1560.72
Total yearly 93349

Woody Point Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 52.2 1618.27
February 113 3164.02
March 209.04 6480.22
April 356.97 10709.2
May 435.6 13503.6
June 443.79 13313.7
July 426.27 13214.5
August 381.88 11838.3
September 292.88 8786.33
October 202.46 6276.2
November 111.49 3344.78
December 53.47 1657.72
Total yearly 93906.9

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.06% angle of incidence loss and -3.27% temperature and irradiance loss. This totals to about -15.61%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Saint-CharlesSainte-GermaineBridgevilleBarachoisVillemontelSaint-Georges-de-MalbaieSainte-RoseSaint-Nazaire-de-BerryGuyenneNotre-Dame-du-RosaireLanguedocSaint-Marc-de-LatourCap-des-RosiersSainte-�lisabeth-de-ProulxPetite-Rivi�re-au-RenardCap-SeizePetit-CapSaint-Maurice-de-l'�choueriePointe-JauneL'Anse-�-ValleauLes BuissonsPort-MenierRivi�re-Sainte-Marguerite-en-BasKegaskaSheldrakeMurdochville